My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1281940
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
93-XXXXX
>
Permit - 1281940
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2011 3:31:33 PM
Creation date
9/3/2003 3:08:13 PM
Metadata
Fields
Template:
Permits
Permit Address
790 MAIN ST
Permit City
Aumsville
Permit Number
93-00897
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DIRECTOR <br />Craig O, I uedeman <br /> <br />BUILDING INSPECTION <br />(503} 588-5147 <br /> <br />PLANNING & <br />ENFORCEMENT <br />(503) 588-5038 <br /> <br />ROARD OF <br />COMM~SSIONERS <br />Randall FranCe <br /> <br />OFFIC~R <br />K~n Roud~bu~h <br /> <br />Marion Count. <br /> OREG · ' <br /> <br />COMMUNITY DEVELOPMENT <br />DE PART _NT: <br /> <br /> 'ILE <br /> <br />DATE: <br /> <br />SUBJECT: <br /> <br />OWNER: <br /> <br />CONTROL NUMBER~ <br />PERMIT NUMBER: <br /> <br />TYPE OF CONSTRUCTION: <br />BUILDING CLASS: <br /> <br />STRUCTUPJ~L PLANS REVIEW <br /> <br /> August 3, 1993 <br /> <br /> 790 Main Et., Aumsville <br /> <br /> Woodrow Billup <br /> <br /> 93-00897 <br /> 45798 <br /> <br /> B-2 (Mini-storage use only) <br /> <br /> The plans for the above indicated project are acceptable as submitted <br /> subject to the following items noted below: <br /> <br />This is a plan review covering the alterations to the above existing building. <br />This review is based on the regulations of the Oregon State Structural <br />Specialty Code ('91 U~C) 1993 ~ditien. <br /> <br />This review is not intended to prohibit the building inspector from requesting <br />an evaluation of the acceptability of existing structural members that may <br />appear to be unsafe. Existing construction not specifically detailed in the <br />plans and structural calculations is beyond the scope of this review. <br /> <br />Exterior walls located less than 20 feet from the property line are <br />required to be of one-hour fire resistive construction. (Table 5-A.) <br />(i.e.: exterior siding, 1/2-inch gypsum sheathing, 2 x 4 studs @ 16-inch <br />centers, 5/8-inch Type X gypsum wallboard) (Table No. 43-B) <br /> <br />Office buildings, retail stores, warehouses and factories or workshops <br />using materials not highly flammable or combustible are classified as <br />Group B Division 2 Occupancies (B-2). Based on the limited information <br />submitted with the plans, this building has been classed as a B-2 <br />Occupancy. The use or storage of highly flammable or combustible <br />materials would cause the occupancy classification to be changed and <br />additional code requirements may be necessary. Contact Marion County <br />Building Inspection if this occupancy classification is not appropriate <br />to your intended use of the facility. (701) <br /> <br />The review is NO~ an approval for leasing these storage spaces for any <br />other uses than mini-storage. Some of the uses not approved in this <br />review are auto repair, cabinet and wood working shops, paint booths and <br />other similar uses. <br /> <br />Every building shall have sanitary fixtures installed as required by <br />Section 510 and Table No. 5-~. Where sanitary fixtures are located in <br />an adjacent building on the same property, toilet facilities may be <br />omitted in the new building. (510(a)) <br /> <br />Senator Building 220 High Street NE Salem, Oregon 9730]-3670 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.