Laserfiche WebLink
~4 Shaw Square Rd, S~, Aumsvill~ <br />93-1649 (47009) <br />June 3~ 1993 <br />Page 1 <br /> <br />M,arion Count;y <br /> OREGON <br />COMMUNITY F)EVELOPM£NT <br />DI[PARJMEN 1 <br /> <br /> Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1990 Edition One and Two Family Dwelling Specialty Code. <br /> <br />4 <br /> <br />11. <br /> <br />30. <br /> <br />36. <br /> <br />37. <br /> <br />Approved numbers or addresses shall be placed on all buildings in such a <br />position as to be plainly visible and legible from the street or road <br />fronting the property. (UFC 10.208) <br /> <br />The grade away from foundation walls shall fall a minimum of 6 in. <br />within the first 10 ft., except as restricted by lot lines where the <br />fall will be a minimum of 6 in. regardless of the horizontal distance <br />available. (R-301.3) <br /> <br />Foundation walls shall extend at least 8 in. above the finished grade to <br />the foundation at all points. (E-304.2) (6 in. where pressure treated <br />sill plates are used.) <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The window sill height sha~l not be more <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2} <br /> <br />When alterations repairs or additions are made to an existing dwelling, <br />the entire building shall be provided with smoke detectors located as <br />required for new dwellings. <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the immediate vicinity of the bedrooms and on each additional <br />story of the dwelling including basements. In dwelling units with split <br />levels, a smoke detector need be installed only on the upper level, <br />provided the lower level is less than one full story below the upper <br />level, except that if there is a door between levels then a detector is <br />required on each level. All detectors shall be connected to a sounding <br />device or ether detectors to provide, when actuated, an alarm which will <br />be audible in all ~leeping areas. (R-215.1) <br /> <br />42. <br /> <br />Ail habitable rooms shall be provided with aggregate glazing area of not <br />less than $ percent of the floor area of such rooms. One-half of the <br />required area of glazing shall be openable. The glazed areas may be <br />omitted in rooms where an approved mechanical ventilation system is <br />provided capable of producing a change of air every 30 minutes, <br />artificial light i~ provided capable of producing an average <br />illumination of 6 footcandles over the area of the room at a height of <br />30 inches above the floor level. <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />