Laserfiche WebLink
Marion County <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br /> DEPARTMENT <br /> <br />L <br /> <br />(503) 582~-5347 <br /> <br />pLANNING ,& <br />EN[tORCEMI~NT <br />(503) 5t~-5038 <br /> <br />COMMISSIONERS <br />Randall Franke <br /> <br />DATB: <br /> <br />SUBgECT: <br /> <br />OWNER: <br /> <br />CONTROL NUMBER: <br />P~RMIT NUMBER~ <br /> <br />~YPE OF CONSTRUCTION~ <br />BUILDING CLASS: <br /> <br />STRUCTURAL PLANS REVIEW <br /> <br /> October l, 1993 <br /> <br /> 12094 Ehlen Rd. NE, Aurora <br /> <br /> CBM Development <br /> <br /> 93-03185 <br /> 49934 <br /> <br /> V-N <br /> <br /> B-2 (office) <br /> <br />The plans for the above indicated project are acceptable as submitted <br />subject to the following items noted below: <br /> <br />This is a Plan Review covering the installation of the above indicated <br />prefabricated building. Plans have been reviewed for compliance with the <br />provisions of the Oregon State Struotural Specialty Code ('91 UBC) 1993 <br />Edition. <br /> <br />This reviaw is not intended to prohibit the building inspector from requesting <br />an evaluation of the acceptability of ~xisttng structural members that may <br />appear to be unsafe. Existing construction not specifically detailed in the <br />plans and structural calculations is beyond the scope of this review. <br /> <br />Ail prefabricated structures which are intended to be sold, leased or <br />installed on a building site in Oregon shall bear a State of Oregon <br />insignia of approval. The insignia shall be permanently attached on <br />each unit in a visible location after installation Of the structure. <br />(5001 & 5OO7) <br /> <br />All unenclosed floor and roof openings, open and glaged sides of <br />~tairways~ landings and ramps, balconies or porches which are more than <br />30 inch~s above grade or floor below, and roofs used for other than <br />service of the buildin~ shall be protected by a guardrail. <br /> <br />Guardrails in araas accessible to the ~ublic shall be not less than <br />42-inches in height. The open space between the intermediate or <br />ornamental pattern of guardrails shall be such that a ~-inc~ diameter <br />sphere cannot pass through. (1712) <br /> <br />~very building shall have sanitary fixtures installed as required by <br />Section 510 and Table NO. 5-E. Where sanitary fixtures are located in <br />an adjacent building on the same property~ toilet facilities may be <br />omitted in the new building. (510(a)) <br /> <br />Senator Building 220 High Street NE Salem, Oregon 97301-3670 <br /> <br /> <br />