Laserfiche WebLink
October 6~ 1993 <br /> <br />A~PLICANT~ <br />SITE NUMBER= <br /> <br />STANDARD SYSTEM CONSTRUCTION DETAIL <br /> <br />CBM Development <br />93-03185 <br /> <br /> Your site has been found suitable for a STANDARD ON-BITE SEWAGE DISPOSAL <br />SYSTEM. The following construction specifications shall apply to the installa- <br />tion of your septic system. <br /> <br /> 1. The septic tank shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />150 gallons per day. Based on soil conditions observed on this <br />site, the disposal field will be sized at 150 lineal feet per 150 <br />gallons of projected daily sewage flow. A minimum of 150 lineal <br />feet of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2) feet wide and <br />on minimum ten (10} foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1") and contoured to follow the natural ground surface. <br /> <br />The disposal field shall be constructed with equal distribution <br />with a minimum trench depth of 18 inches and a maximum trench <br />depth of 24 inches. There must be at least 6 inches of backfill <br />over the top of the gravel, measured from the natural ground <br />surface. <br /> <br /> An effluent lift pump will be necessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS= <br /> It is my understanding that a permit for a holding tank is being <br /> requested while negotiations are underway to extend a sewer line from <br /> the City of Donald to the Aurora I-5 freeway interchange. The proposal <br /> is to use a holding tank on this property for a period not to exceed one <br /> (1) year. At the end of the year, the property would either be connected <br /> to the Donald sewer system or an on-site sewage system disposal field <br /> would be installed according to the above specifications. The minimum <br /> holding tank size is 1500 gallons and an alarm is required in the tank <br /> at the 75 percent full level. The attached permit is valid for a period <br /> of one year and the system must be installed as specified within that <br /> time period -or- the property must be connected to a public sewerage <br /> system within the same one year period. <br /> The approved area for construction of the septic system disposal <br /> field is located south of the loop gravel driveway in the area of the <br /> number 4 test pit. <br /> <br />THIS IS NOT A P~RMiT TO INSTAIJ~ THE SEPTIC SYSTEM. DO NOT INSTALL TEE SYSTEM <br /> <br />UNTIL A VALID PERMIT HAS BEEN ISSUED BY THIS OFFICE. <br /> <br /> <br />