STANDARD SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />August 13, 1993 <br /> <br />APPLICANT: ANNETTE BISSELL <br />SITS NUMBER: 93-2632 <br /> <br /> Your site has been found suitable for a STANDARD ON-SITE SEWAGE DISPOSAL <br />SYSTEM. The following construction specifications shall apply to the installaw <br />=ion of your septic system. <br /> <br /> 1. The septic tank shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br /> 2. The projected daily sewage flow for this project is calculated at <br /> 450 qallons per day. Based on soil conditions observed on this <br /> site, the disposal field will be sized at 150 lineal feet per <br /> qallons of projected daily sewage flow. A minimum of 450 lineal <br /> feet of disposal field will be required for your proposed develop- <br /> ment. The disposal trenches are constructed two (2) feet wide and <br /> on minimum ten (10) foot centers and with no line exceeding 125 <br /> feet in length. The trenches and perforated pipe are installed <br /> level (±1") and contoured to follow the natural ground surface. <br /> <br /> 3. The disposal field shall be constructed with seria%, distribution <br /> with a minimum trench depth of 24 inches and a maximum trench <br /> depth of 24 inches. There must be at least 12 inches of backfill <br /> over the top of the gravel, measured from the natural ground <br /> surface. <br /> <br /> A groundwater interceptor is required as part of this system. This <br />interceptor trench mast be constructed a minimum twelve (12) inches wide by 42 <br />inches deep with 36 inches of clean gravel placed over a four (4) inch smooth <br />wall perforated pipe. The interceptor must be located at least ten (10) feet <br />upslope from the disposal field and must discharge through a watertight, non- <br />perforated pipe beside or below the disposal field. A separation of 25 feet is <br />required from the septic tank if the tank is located upslope of the groundwa- <br />ter interceptor. <br /> <br /> An effluent lift pump may be necessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS: <br /> Construct the drainfields within the immediate area of the three most <br /> northerly test pits. The lower pits are too close to the building <br /> excavation. A pre-construction field stakeout is recommended to estab- <br /> lish the locations and elevations of the individual drainlines. Refer to <br /> stakeout p~ocedure and the ~etba~k list for details to complete the <br /> stakeout. A list of licensed installers who can assist with the stakeout <br /> is enclosed for your convenience. Both the original and replacement <br /> fields should be staked for location. Use care not to alter the natural <br /> topsoil within the proposed drainfield sites. Drainfields can only be <br /> installed into the natural undisturbed topsoil. Submit a detailed to- <br /> scale-drawn plot plan of the stakeout to our office as soon as possible. <br /> Soil conditions are marginal, so construction should be limited to the <br /> dry soil summer season. <br /> <br />THIS IS NOT A PERMIT TO INS~aT~. THE SEPTIC SYSTEM. DO NOT INSTALL THE SYSTEM <br />UNTIL A VALID PERMIT HAS BEEN ISSUED BY THIS OFFICE. <br /> <br /> <br />