STANDAi~D SYSTEM CONSTRUCTION DETAIL <br /> <br />August 31, 1992 <br /> <br />APPLICANT: <br />SITE NUMBER: <br /> <br />PATSY SMITH <br />92-3000 <br /> <br /> Your site has been found suitable for a STANDARD ON-SITE SEWAGE DISPOSAL <br />SYSTEM. The following construction specifications shall apply to the installa- <br />tion of your septic system. <br /> <br /> 1. The septic tank shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br /> 2. The projected daily sewage flow for this project is calculated at <br /> 450 qallons, per day. Eased on soil conditions observed on this <br /> site, the disposal field will be sized at 150 lin~a1 feet per 150 <br /> qallons of projected daily sewage flow. A minimum of 450 lineal <br /> feet of disposal field will be required for your proposed develop- <br /> ment. The disposal trenches are constructed two (2) feet wide and <br /> on minimum ten (10) foot centers and with no line exceeding 125 <br /> feet in length. The trenches and perforated pipe are installed <br /> level (~1") and contoured to follow the natural ground surface. <br /> <br /> 3. The disposal field shall be constructed with serial distribution <br /> with a minimum trench depth of 24 inches and a maximum trench <br /> depth of 24 inches. There must be at least 12 inche~ of backfill <br /> over the top of the gravel, measured from the natural ground <br /> surface. <br /> <br /> An effluent lift pump may be necessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> A groundwater interceptor is recruited as part of this system. This <br />interceptor trench must be constructed a minimum twelve (12) inches wide by 42 <br />inches deep with 36 inches of clean gravel placed over a four (4) inch smooth <br />wall perforated pipe. The interceptor must be located at least ten (10) feet <br />upslope from the disposal field and must discharge through a watertight, non- <br />perforated pipe beside or below the disposal field. A separation of 25 feet is <br />required from the septic tank if the tank is located upslope of the groundwa- <br />ter interceptor. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS: <br /> The drainfields must be constructed within the immediate area of the <br /> soil test pits and no farther down slope. There is a moderate to severe <br /> rock hazard associated with drainfield construction. Rock larger than <br /> six inches must be removed from backfill material. Refer to the enclosed <br /> setback list which outlines minimum separation distances between <br /> components of septic systems and other features. Soil conditions are <br /> marginal, so summer season construction is recommended to prevent <br /> excessive soil compaction within the drainfield and replacement areas. <br /> <br />THiS IS NO~ A p~W~TT TO INSTALL ~HE SE~C SYSTEM. DO NOT INST~73- THE SYSTEM <br />UNTIL A VALID PERMIT HAS BEEN ISSUED BY THIS <br /> <br /> <br />