Laserfiche WebLink
Mar!qn' County <br /> <br /> OREGON <br />COMMUNITY D~'VELOPMI~NT <br />[DEPARTMENT <br /> <br />NOTICE OF DENIAL: <br /> <br />EVALUATION REPORT FOR AN <br />ON-SITE SEWAGE DISPO.~AL SYSTEM <br /> <br />August 27, 1992 <br /> <br />PHILIP @ DEBRA QUINTON-COX <br />3746 SW COMUS <br />PORTLAND, OREGON 97219 <br /> <br />SUBJECT: <br /> <br />SITE ~92-450, T=10S, R:SE, S=01 <br />SITE ADDRESS= 165 CLIFFORD AVENUE, DETROIT, OREGON 97342 <br /> <br />An evaluation has been made of the above described property proposed for <br />installation of an on-site sewage disposal system. AS a result of that <br />investigation, it has been determined that the site specified on your applica- <br />tion does not qualify for a standard septic system or any of the alternative <br />systems. The conditions on the site do not meet the minimum requirements of <br />the Department of Environmental Quality On-Site Sewage Disposal Rules. These <br />rules are specified in Oregon Administrative Rules, chapter 340, Division 71, <br />Sections 100 through 600. consequently, this site must be denied. <br /> <br />The principal reasons for denial of this site are related to parcel size and <br />setbacks. The following paragraphs outline the specific reasons for this <br />denial. <br /> <br />PARCEL SIZE AND SETBACKS: <br /> 1. There is insufficient area on the property for installation of an <br /> approved on-site septic system which will meet the setbacks as <br /> required in the D.E.Q. rules. The setbacks which are of particular <br /> concern are circled on the attached sheet. Each lot or parcel must <br /> have sufficient usable area available to acco~m~odate an initial <br /> and replacement septic system. <br /> <br />ADDITIONAL cOMMENTS= <br /> We can re-consider this property with a detailed field stakeout to <br />establish whether there may be enough area to construct any of the alternative <br />septic systems. Refer to the enclosed stakeout procedure for details to <br />prepare the site for re-evaluation. The property corners and property lines <br />must be clearly flagged and strung for location. If you choose to prepare the <br />property for re-evaluation, notify this office of your request in writing and <br />within ninety (90) days of the initial site evaluation. <br /> <br />The alternative SAND FILTER system appears most likely for re-consideration, <br />because less drainfield is necessary. The required amount of drainline for <br />each drainfield of the sand filter system for the proposed three bedroom <br />residence is ninety (90) lineal feet. The amount of drainfield line for each <br />drainfield of a standard system for the same residence is 225 lineal feet. The <br />lines must be contoured to the natural landform surface, configured in serial <br />distribution, with the drainline trenches limited to 24 inches deep minimum <br />and 30 inches deep maximum. A list of licensed septic system installers is <br />enclosed for your convenience. Any of these installers should be able to <br />assist you in preparing the site for re-evaluation. <br /> <br /> <br />