Laserfiche WebLink
11698 Warbler Ln. NE., Aurora <br />93-3836 (9051364) <br />November 24, 1993 <br />Page 1 <br /> <br />Marion County <br /> <br /> OREGON <br />COMMUNITY E)EVELOPMENT <br />DEF'ARTMENT <br /> <br />Buildlng Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for complianse with the State of Oregon <br />1993 Edition One and Two Family Dwelling Specialty Code. <br /> <br />A copy of approved plans when required by the building official shall be <br />kept on the site of the building or work at the time of inspection. <br /> <br />11. <br /> <br />Footings sections: 12 in. wide - 1 story~ 15 in.- 2 story, 18 in. 3 <br />story. Footings shall extend not less than 12 in. below the finish <br />natural grade. <br /> <br />12. <br /> <br />Foundation walls shall extend at least 8 in. above the finished grade to <br />the foundation at all points. (R-304.2) (6 in. where pressure treated <br />sill plates are used.) <br /> <br />20. <br /> <br />62. <br /> <br />Foundation plates shall be bolted to the foundation with minimum <br />1/2 inch di~eter by 10 inch anchor bolts embedded at least 7 inches <br />into concrete or reinforced masonry and spaced not more than 6 feet <br />apart with a minimum of 2 bolts per piece with one bolt within 12 inches <br />of the end of each piece. Figure (R-303) <br /> <br />Roof trusses are required to be designed by an Oregon registered <br />Engineer or Architect. For trusses manufactured by an approved <br />fabrication plant, have the design and layout drawings available at the <br />construction site for the framing inspection. All job site cutting or <br />modification of the roof trusses shall be clearly shown in the <br />engineer's design calculations and drawings. If trusses are to be built <br />at the job site, submit the engineer's design and construction plans to <br />the Marion County Building Department prior to start of construction and <br />have the approved drawings available at the site for the framing <br />inspection. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />sf <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />