My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1287513
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1287513
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2023 2:31:30 PM
Creation date
9/4/2003 8:55:39 AM
Metadata
Fields
Template:
Permits
Permit Address
10921 MARTIN LN NE
Permit City
Aurora
Permit Number
94-02876
Parcel Number
031W32CA01002
Permit Type
SEPTIC
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
October 14, 1993 <br /> <br />A~PLICANT= <br />SITE NUMBER: <br /> <br />STANDARD SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />John Davidaon <br />93-03259 <br /> <br /> Your site has been found suitable for a STANDARD ON-SITE SEWAGE DISPOSAL <br />SYSTEM. The following construction specifications shall apply to the installa- <br />tion of your septic system. <br /> <br />1. The septic tank shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />450 gallons .per day. Based on soil conditions observed on this <br />site, the disposal field will be sized at 150 lineal feet per 150 <br />g~llons of projected daily sewage flow. A minimum of ~50 lineal <br />fee__t of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2) feet wide and <br />on minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1") and contoured to follow the natural ground surface. <br /> <br />The disposal field shall be constructed with ~er~al distribut~q~ <br />with a minimum trench depth Of 24 inches and a maximum trench <br />depth of 24 inches. There must be at least 12 inches of backfill <br />ever the top of the gravel, measured from the natural ground <br /> <br /> A groundwater interceptor is required as part of this system. This <br />interceptor trench must be constructed a minimum twelve (12) inches wide by 48 <br />inches deep with 36 inches o~ clean gravel placed over a four (4) inch smooth <br />wall perforated pipe. The interceptor must be located at least ten (10) feet <br />upslope from the disposal field and must discharge through a watertight, non- <br />perforated pipe beside or below the disposal field. A separation of 25 feet is <br />required from the septic tank if the tank is located upslope of the groundwa- <br />ter interceptor. <br /> <br /> This approval is site specific to the area teste~ and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS= <br /> See the attached setback table for minimum separation distancea. <br /> setbacks of particular importance on this site are highlighted. <br /> <br />Those <br /> <br />THIS IS NOT A PERMIT TO INSTALL TEE SEPTIC SYSTEM. DO NOT INSTALL THE EYETEM <br />UNTIL A.,,VALID PEEM~T HAS BEEN ISSUED BY %"HIS OFFICE. <br /> <br /> <br />