Laserfiche WebLink
8231 N SANTIAM HWY SE, AUMSVILLE <br />November 23, 1994 ~: ~: · ~ ~.~ ~% : <br /> <br />9. This plan uses an ENGINEERI~D DESIGN to meet the lateral wall <br /> bracing requirements of the cede. INSURE THAT ~ DETAILED <br /> CONSTrUCTiON REQUIREMENTS S~W~ O~ THS~N.S:AN~.ON THE ATTACHED <br /> 8 1/2 xll ENGINEERING SHEE~'ARE:FO~. ~..- <br /> <br /> 10. Chimney shall be provided with crickets when the dimension parallel to <br /> the ridgeline is greater than 30 inches. The intersection of the <br /> chimney shall be flashed and counterflashed. (R-901.15) <br /> <br />11. Wood beams, joists, headers and studs shall not be placed within 2 <br /> inches from the outsld~ face of a masonry chimney built partially or <br /> entirely within the dwelling. Masoary chimneys built entirely outside <br /> the dwelling may be placed 1 inch minimum from combustible material. <br /> (R-901.13) <br /> <br /> 12. Factory-built or masonry fireplaces shall be equipped with an exterior <br /> air supply to assure proper fuel combustion. (R-906.1) <br /> <br /> 13. THE DETAIL SNOWN FOR THE SLAB EDGE INSULATION IN THE BASEMENT NEEDS TO <br /> BE CHANGED. THE INSULATION SHALL NOT BE PLACED BETWEEN SLAB EDGE AND <br /> BASEMENT WALL.(WALL USES SLAB TO ~SIST SLIDING) <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the previsions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />DAW <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />