Laserfiche WebLink
P R ES C R I PT I E E",M/.A EL'."B IR .¢~:q I N G <br /> · :'---"- ::-'.: <br /> BRACED AND ALTERNATE BRACED WALL PANEL <br /> CONSTRUCI]~N ~SCH[~I~U~E: <br /> <br /> BP (BRACED PANEL) 4' MIN, LENGTH <br />FRAMING - MEET CODE REQUIREMENTS FOR SIZE AND SPACING OF STUDS. <br />SILL PLATE/ANCHORAGE - PRESERVATIVE TREATED 2X WITH 1/2" DIA. X 10" A.B. AT 48" C.C. <br />SOLE PLATE/ANCHORAGE - MINIMUM 2X PLATE FASTENED TO FLOOR FRAMING WITH 16d <br /> COMMON NAILS AT 16" ON CENTER. <br />SHEATHING -MIN. 1/2" INDEX 24/0 CDX PLYWOOD PROVIDE 2" NOMINAL BLOCKING AT ALL <br /> PLYWOOD JOINTS. <br />FASTENERS - 8d COMMON NAILS OR 14 GA. X 2" X 7/16" CROWN STAPLES <br />FASTENER SPACING - 6" O,C. ALONG PLYWOOD PANEL EDGES. 12" C.C, iN FIELD <br /> <br />iBP (INTERIOR BRACED PANEL) 8' MIN. LENGTH <br />FRAMING - MEET CODE REQUIREMENTS FOR SIZE AND SPACING OF STUDS. <br />SOLE PLATE/ANCHORAGE - MINIMUM 2X PLATE FASTENED TO FLOOR FRAMING WITH 16d <br /> COMMON NAILS AT 16." ON CENTER. PROVIDE DOUBLE JOIST UNDER PARALLEL <br /> WALLS AND BLOCKING UNDER PERPENDICULAR WALLS. <br />SHEATHING - liE' GYPSUM APPLIED TO ONE SIDE OF WALL. PROVIDE 2" NOMINAL BLOCKING <br /> AT ALL PLYWOOD JOINTS. <br />FASTENERS/SPACING - 1 1/4" DRYWALL NAILS AT 7" ON CENTER, OR 1 1/4" TYPE W SCREWS <br /> AT 6" ON CENTER AT EDGES AND 12" ON CENTER IN FIELD. <br /> <br /> <br />