Laserfiche WebLink
830 LZNCOLN STREET, AUMSVILLE <br />January 30, 1995 <br />Page 2 <br /> <br />10. <br /> <br />11, <br /> <br />12. <br /> <br />14. <br /> <br />lS, <br /> <br />16- <br /> <br />The TJI ~loor joists shall be installed in accordance with its listing <br />and M.F.~. installation instructions. <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue~ The window sill height shall not be more <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet, (R-210,2) <br /> <br />Openings between the garage and residence shall be equipped with either <br />solid wood doors not less than 1 3/8 inches in thickness or 20-minute <br />fire rated doors, or equivalent. (R-209,1) <br /> <br />Water heaters installed in Seismic Zone 3 or ~ are required to be <br />secured to resist displacement due to earthquake motion_ <br />(Interpretative Ruling No~ 93-94, <br /> <br />Moating and cooling appliances located in a garage shall be pro~ected <br />from impact by automobiles. <br /> <br />In new construction, required smoke detectors shall receive their <br />primary power from the building wiring and when primary power is <br />interrupted, shall receive power from a battery. (R-215~2) <br /> <br />A readily accessible attic access shall be provided to any attio area <br />having a clear height of over 30 inches. A framed opening no~ less than <br />22 in. by 30 in. is re~uiredl (R-708) <br /> <br />Wood trusses shall be designed in accordance with approved engineerin~ <br />practice, Trusses shall be braced according to their appropriate <br />engineered design. Truss members shall not be cut or altered unless so <br />designed, (R-702.9) <br /> <br />In scissor trusses loose fill insulation is not allowed when there is <br />less than 44 inches of headroom and/or the interior oe,ilin~ <br />exceeds 2 in 12. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid~ <br /> <br />MLJ <br /> <br /> "APPROVED" only when this sheet is <br />attached to plans <br /> <br /> <br />