Laserfiche WebLink
7 1 5 9 T H $ T ,. A. U M S <br /> <br />Page ~ <br /> <br />V I L L E <br /> <br />A Gypsum brace panel is an 8' section of wall (or 4' section blocked on <br />both sides) that has all ed~e~oef t~e ~m ~ane%s blocked. It shall be <br />screwed or nailed off as per ~6. ~Aclhed~¥~ ~st~llation is not <br />allowed. ~., · - · · <br /> <br />10. <br /> <br />In scissor trusses loose fill insulation is not allowed when there is <br />less than 44 inches of headroom and/or the interior ceilinq ~,l,ope <br />exceeds 2 in 12. <br /> <br />11. <br /> <br />Any ceiling is considered vaulted when the ceiling slope is 2/12 or <br />greater. Insulation in a flat ceiling (slope less than 2/12) shall have <br />a minimum rating of R-38. Insulation in vaulted ceilings may have a <br />minimum rating o~ R-~0, for a maximum of 50% of the tot~,~ ,heated floor <br />space area. (Ore,on Energy Code) <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presumin~ to give authority to violate or cancel the provisions of the <br />dwellin~ code or of other ordinances of the jurisdiction shall not be valid, <br /> <br />DAW <br /> <br /> <br />