My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1290494
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
95-XXXXX
>
Permit - 1290494
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2011 8:50:20 AM
Creation date
9/4/2003 10:06:29 AM
Metadata
Fields
Template:
Permits
Permit Address
7732 SUNNYBROOK LN SE; 7732 75TH PL SE
Permit City
Aumsville
Permit Number
95-00010
Parcel Number
082W26C 01501
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Juno 17, 1994 <br /> <br />APPLICANT: <br />SITE NUMBER~ <br /> <br />SAND FILTE~.,,SYSTEM CONSTRUCTION DETAIL SHEE~ <br /> <br />KIM & KEN ALLEN <br />94-2173, WEST P/O (1.5 ACRES) T/L 1501 <br /> <br /> Your sito has boon found suitablo for a SAND FILTER ALTERNATIVE S~WAGE <br />DISPOSAL SYSTEM. The following construction spocifications shall apply to the <br />installation of your septic system. <br /> <br />The septic tank shall have a minimum liquid capacity of 10Q~ <br />gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />450 qal%qns per day. Eased on soil conditions observed on this <br />site, the disposal field will be sized at 45 lineal feet per 150 <br />qallons of projected daily sewage flow. A minimum of 135 lineal <br />feet of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2) feet wide and <br />on minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1"} and contoured to follow tho natural ground surface. <br /> <br />The disposal field shall be constructed with equal distribution <br />with a minimum trench depth of 18 inches and a maximum trench <br />depth of 18 inches. There must bo at least 6 inche~ of backfill <br />over the top of the gravel, measured from the natural ground <br />surface. <br /> <br />The sand filter system shall be designed and operated as per OAR <br />340-71-290 through 340-71-305. Detailed plans for the system must <br />be submitted prior to permit issuance. A building permit is <br />roquired if a site built concrete box is used as the sand filter <br />container. A pamphlet is available in our office which details the <br />requirements for a sand filter system. <br /> <br /> An effluent lift pump may bo necessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS~ <br /> The sand filter drainfield must be installed within the immediate area <br /> of the uppermost (northeasterly) test pit. It might be necessary to <br /> elevate tho sand filter to achieve gravity flow into the shallow <br /> drainfield lines. A capping fill will be required with the sand filter <br /> replacement drainfield with the lines limited to 12 inches deep. Soil <br /> conditions are marginal, so uso care not to disturb the soil surface <br /> prior to installation. A pre-construction field stakeout is recommended <br /> to establish the elevations and locations of the individual drainfield <br /> lines for both systems prior to siting the house and well. Refer to the <br /> stakeout procedure and the setback list for details to complete the <br /> stakeout. Observe all normal setback and separation distances. <br /> <br />THIS IS NOT A PERMIT TO INSTALL THE SEPTIC SYSTEM. DO, NOT INSTaT3. THE SYSTEM <br />UNTIL A VALID PERMIT HAS BEEN ISSUED BY THIS OFFICE. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.