Laserfiche WebLink
8 5 0 L I N C 0 ~ ,.'$ .T., '~ ' A U M S V I <br />January 5, 1995 : · .- .. <br /> <br />L L ~ <br /> <br />10. <br /> <br />on the plans and cons~za~t?l as sh~wn~ . <br />In scissor trusses lo~se f ~ in~u~tien.~s not allowed when there is <br />less than 44 inch,5 of headroom and/or ~he interior ce$1ing slope <br />exceeds 2 in 12. <br /> <br />Any ceiling is considered vaulted when the ceiling slope is 2/12 or <br />greater. Insulation in a flat ceiling (slope less than 2/12) shall have <br />a minimum rating of E-38. Insulation in vaulted ceilings may have a <br />minimum rating of R-30, for ~..~aximum of 50%. of the total heated floor <br />space area. (oregon Energy Code) <br /> <br />THE FoLLOWINS ITEMS WERE ADDED/CLARIFIED XN A PHONE CONVERSATION WITH DILL <br />~ 1/4/95. <br /> <br />11. ENERGY PATH SHALL BE PATH <br /> <br />12. 2 AHP'$ ARE BEING ADDED TO TEE FRONT OF THE GARAGE FOR LATEI~J~ B~ACING. <br /> (DOOR SIZE WILL BE SMALLER) <br /> <br />13. 8' OF THE ~ACK WALL OF THE GARAGE IS BEING USED AS A GYPSUM ~RACE PANEL. <br /> a?~, EDGES OF THE ~¥PSUM PANEL SHALL BE BLOCKED IN THIS 8' AREA. (ONE <br /> SIDE OF WP,~L ONLY) <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />DAW <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />