Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours; 8:00-4:30 * Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 588~7904 <br /> <br />DATE/TIME : ~7/1~/75 11=57 STATUS : ISSUED <br />PERMIT MO : 95-12745 APPLIED : <br />TYPE : SP ISSUED = ~7/i~/i995 <br />CRASS : TO EXPIRE : <br />OCCUPANCY : R-~ PACE 2 <br /> <br /> SEPTIq PERHIT <br />This ',~roperty was previously evalated 03/14~1978 for the feasibility ,l~o inst,~ll <br />septic sys'Eem for a R~SIDENTIAI_ building $~le. Based on t~e results Of this studF~ site <br />approval wes g~a~'ked~ The approv~l is s~te s~ecific to the area tested~ a~'~d th~ septic <br />~.ysteM. . must...b'~ .]oca'-e~ ..... i~. the. immediate, area. of the. .- ~est. _P'[ts,. ~les~..~therwise. _ auth rLzed. .... <br />by this off,ce, A new s~te evaluat:[o~ may be~ required if tl~e system is proposed for <br />different area on ~he proper~y. <br />~h~s approval wes given o~ the basis ~hmt the~ lo~ or parcel w~.ll not be further partitioned <br />or subdivided and that cond:[t~ons o~ this progerty and on ad~aEen~ properties are not a:l,'[:ered <br />~,n any ma~e~' which wo[[lO proh+J, bi'~ the issua~e o~ m perlqi~. Soils in the apo~'oved <br />sha~l ~ot be alta"ed by c~t~:[ng, fill~Y~g, or ,o'~er develop~e~tal activities which would <br />:i, lqpede the successful operatio~ of the znitiail or replacement absorption syseems. Failure <br />to comply w~.th ~he above ieems may void this ?pproval, <br />The si~e evsluation approval runs with ehe la~d,~ bu~ the pel"lqSt is ~mn-trsnsferable ~md non,-, <br />re'h.mdab le. m <br />Kee , ~hi~: document witli your records. Show this permit to tile septic iY)staller pr:i, of to <br />installation of the system. Any deviate, on frpm the approved plan must have prior approval <br />this office. <br /> <br />The following construction specifications sha~.l mppIy to the ~.nst~l].lation of the ini~ial <br />septic syste~: <br /> <br /> TYPE OF INITIAL SYGTEH: STANDARD <br /> MIHtMUM SEPTIC TANK CAPACITY: 1~8~ G~LLONS <br /> LINEAL FEET OF DRAINFIELD: <br /> TYPE OF DISTRIBUTION: SERIAL <br /> DISPOSAL T~ENCH DEPTH: 24 INCHES~ H:[NIMUH;24 II,IgNES, MAXIHOM <br /> TOTAL BRAIN MEDIA DEPTH: 12 INCBES <br /> ~RAIN ME~IA UNDER PIPE: 6 INCHES <br /> MINIMUM SQIL BACKFILL: 12 INCHES <br /> <br /> The disposal ~re~ches are constructed ~ (~) feet ~de ~nd on mlnimumn teo <br /> at~d with no line exceedin~ 12~ feet ~n length. The trenches aod perfon:rbed pipe are <br /> installed level (+/- one ~ncb) and contoured ~o follow the natural ~round surface. <br /> <br /> TYPE OF FUTHRE REPLACEMENT SYSTE~: STANQA~ <br /> <br /> COMMENTS AND CONDITIONS <br /> <br /> ~. The at~ached ORANGE CARD Must bW posted at' the countx road. <br /> 2. The site Mus~ be protec'~eO fron/trmffAc," lgvestock~ farmgnQ <br /> or other dal~agin9 activ~ttes, i <br /> 3. This system Must be inspected p,ior ~o cover. To request <br /> mo inspmct$o~ of co~pleted work~ call 588.-7~4 (24-boL[¥- <br /> li~m). When reques~n~ ehe inspection, be sure to give <br /> J, nstaller~s naMe~ phone number~size o{~ tank~ end total <br /> Jet,th of drai~fle[d. I~spect~On w~ll be completed within <br /> seven daym of request. <br /> 4~ THI,~ SEPTIC REVIEW WAS COHPLETE~ BY LEE A. GRI~ES ON JULY 7,~ <br /> ~99~, REFER TO REVISED SITE PLA4 DATE~ ~LLY 7, 1~5. DRAIN-. <br /> FIEL9 MUST BE SITED UP-SLOPE OF ~UPPERflOST I'EST PIT. <br /> S'F;~HCTION FIE'LD ,~TAIsEOU[ RECOMHENDE~ PRIOR TO ANY EXLAVA~iOf <br /> REPLACEMENT I)RAINFIELD CAN BE CONSIQEREb ACROSS THE SWALE IN <br /> THE SOUTHEAST CORNER OF THE PROPERTY., OBSERVE ALL USUAL SE'I.-, <br /> <br /> <br />