My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1293497
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
95-XXXXX
>
Permit - 1293497
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2011 1:09:32 PM
Creation date
9/4/2003 12:29:45 PM
Metadata
Fields
Template:
Permits
Permit Address
19762 OLMSTEAD RD NE
Permit City
Aurora
Permit Number
555-95-13934
Parcel Number
041W19C 00600
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE * Room 132 * Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 · Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 588-7904 <br /> <br /> DATE/TIHE <br /> PERflIT NO <br /> TYPE <br /> CLASS <br />,, OCCUPANCY <br /> <br /> BUILDTNG PERltl'T <br /> <br /> : ~5-13934 ~PPLIED : ~7/G6/19~5 <br /> : Resident. addi~io~/el~eratio~ , ISSUED <br /> : ~elling addition~alteration TO EXPIRE : ~2/25/1~9~ <br /> <br /> C) 6~ openings ~oond ve~ pipes~ duc~s, chimneys ~d <br /> fireplaces at ceiling ~Dd ~=loor level, with <br /> <br /> 14. Every sleeping room shall h~ve a~ least one operable window <br /> approved for emergency egre~s o~ rescue. The window sill <br /> he~.ght sl~all no~ be ~o~e"~han 4q incl~es ebove ~'e <br /> The" minimum ne~ clear ope~ng width dimension she~l be <br /> i~ches. The miDim[m ne~ ope~ing~ I~eigh~ sl~all be 24 ~nches. <br /> The minimum m+~ clear opening ~ea ~hall be a~ leas~ 5.7 <br /> square fee'S:. (R-218.2) ' <br /> t5. I~ seismic zone ~. water he:aterS: Shall be anchored or <br /> strapped to resis~ horizontal d~.splaceMent due to <br /> emrthquake Motion. (P-171~ ~(e) )' <br /> 1~,. Whe~ alterations repairs or: additions are mcde to 8m <br /> existing dwellinq~ ~he entire ~uildi~g shall be provided <br /> with s~,~Cke de'~e~orm located 8s requ5 rcd for oew dwe]] ings. <br /> (R-~lS. 1) SMoWe de~ectors ~s~ al~: be i~s~alled oktts~de of" <br /> e~el~ mepar~te slee~iog area: in the iMMediate V~Cin~ty of tl~e <br /> bedrooM. SMoke de~ec~orm shall ,receive their ~r~:ma~y po~er <br /> fro~ ~he building wiring a~ uhe:n primary power zs <br /> ~nterrr~pted, shall receive power from a battery. <br /> 17. Bathrooms shall be providmJ withartif~cia[ ligSt a~d <br /> approved Mechanical ~ent~lat~on ~mysteM ca~able of ~roduc:~g <br /> a chamge of air ovary 12 m~utes or a witOow of not les~ ' <br /> than ~ sg. ftc, one-half of whic~ Must be openable. <br /> lB. IDd~vldual ~l~zed.areas sn ~ha~ardous locat, ions ~hall pass <br /> ~he '~est (CPSC 15 ~FR) regu:~reme~ts of Sectio~ R-288.~ <br /> Jsafety~glazing)~ . ~4 i~'~hes o'~' a door. <br /> ~. in door~ ano ~ithin <br /> B. Fixed a~d sliding pmmelsof slldl,~g-type doors <br /> (pm~io type)~ <br /> C. Gla~ing in s~orM doors. <br /> D. Clazi~ ~n shower an~ bathtub doors add enclosures. <br /> E. Fixed' panels with an area:: in excess of 9 square feet <br /> aod *Oho lowest edge ~less:~han 18 io:~es above ~he <br /> finimhed floor. :: <br />1~). This dwelling plan uses Bra~e Wa~l Penels (BP) '~o P~eet the <br /> code req~lireMe~ for latera~l wall bracing. Insure that ali <br /> BP's are located as imdic~ted.oo'the pl~m,, " ' ' <br />28. Provide screened a~tic vents with :a net free a"ea of <br /> of ~l~e a~ic area (or 1/388:if half is along eaves add ~he <br /> other half in the upper por~ion)~ (R-7~7) <br />21. A readily accessible a~tlc access sl~all be provided to aDy <br /> a~ic area having a clear h~igh~="Of over 38 inc[es. :A <br /> fra~,~ed opeming ~ot less thah 22~i~. by Jg in. is required~ <br /> (R-788) ~ - <br />22. Roof trusses are reguired to be designed by an Oregon <br /> registered EDgineer or A~chi~ect:. For trusses Manufactured <br /> by ao approve8 fabricatioD Dlant~ have ~he desion and <br /> ,.ayout dr~uzngs available a~ ~h~.coD~?uction s~E for <br /> framing iospe~t~.on. All joe si~e cu~'~'ing or <br /> of the roof trusses shall be clebrlX sho'~D in the <br /> engineer's design calculations a~td 8rawiDqs. I~ is assi~ed <br /> that the ~russ will be bearing 0n ~he ExtBrior Wall. on the <br /> ~ot"h sid~ of ~he addition an0 On ~M~e 3':[/8" X 7-1/2" <br /> on the Sou-~h side. .. <br /> <br /> ,;i~,DrVJ, C[L,~ repair and ~:p[abehen~:~hout r~ov~ng per~anent <br /> im::hes of working space and~pla~=for~ ~halt be pr'ov~.ded <br /> front of the control side tO set. Vice the appliance. <br /> <br />?~,, F'ueJ DHrDing eq~d. pmeD'[' shall be provided wi[;ll 8 su'P[ic:ien'[': <br /> su') ~].y of air ~'or '[%u,~l r:m,tbust:~on~ dFaft hood cl:i. lut:i, on <br /> vent:ia'ion of the space :,H whic'~ t'm equ:Lpl,~eD't ~s <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.