Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE * Room 132 * Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 · Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 588-7904 <br /> <br /> AUTHORIZATIOfl/MAJORREPAIR PERMI~ <br />DATE/TIME : 18187195 ,1~:~1 ~ERNIT NO = 95-15§97 <br />TYPE = SP ~ ' STATUS = ISSUED <br />OCCUPANCY : R-3 I.~SUED : 1~/e?/1995 <br /> <br /> AUTHORIZATION/MAJOR REF'AIR PERMIT <br /> <br />This Aut'horization Notice ss for an inspectioo of the e:xistin~ septic syste~ serving a RESIDENTIA <br />b~ldi~g. An i~spection o~ ~he ~yste~ has deter~ined 'that ~be system :Ls 'Fa'.llin~:~ and :L~ need o'~:' I <br />repair. Based on the results of that ~nspect~on, the sXmteM im ~ot 8pproved fo~ the use pro?.'.~s~:-x:~l <br />in your application, Site aporoval has bee~ ~ranted a~cI 'the.~pro~erty is approved 'For the <br />installa'~o~ of a new syste~.' This approval is site specif[E an~ m,~us~ be i~'~stalled ~cc('.~r'd:irx~ <br />the followin~ specifications and the attached site plan. ~= - <br /> <br />Soils in the approved area shall not be altered or ~mdi~ied by cuttin9~ 'Filli~g, or other <br />activities which would 1~pede the successful operatie~ o~ t=he septic syste~ Observe <br />required setback/separation distances during the installa~ion of the syste~,~. <br />Keep this docu~ent with your records. Give a copy of this BerMit to tl~e septic syste~ <br />insta[],er prior to the i~stallation of the syste~. Any deviation fro[~ the approved pla¥~ <br />~ust have prior approval, fro~ ~his o'~fice <br /> <br />The following construction specificatio~s shall apply '~o 'the i~s~allatio~ o'~ the septic s.y'~'t~..~:' .... <br /> TYPE OF REPLACEMENT SYSTEM: STANDARD <br /> <br /> MINIMUM SEPTIC TANK CAPACITY: 1888 GALLON~ <br /> LINEAL FEET OF ORAINFIELD: 225 <br /> TYPE OF DISTRIBUTION: SERIAL <br /> DISPOSAL TRENCR 9EPTH: 24 INcREs,~ MINiHUM~3&==INCHES~ MAXIMUM <br /> TOTAL DRAIN ME~IA DEPTH: ].2 INOHES <br /> DRAIN MEDIA UNDER PIPE= 6 IWCHES <br /> MINIMUM SOIL BACKFILL: ,12 INCHES <br /> GROUND WATER INTERCEPTOR: N <br /> The disposal trenches are constructed :?~o (2) feet wide and on ~it~ieu,~ ten (1~) foot <br /> ce~ers~ The trenches and pipe are installed level (~/s one i~ch) f'rcm the box t~ <br /> the end of the trench and contoured to:follow the natural ground surface. <br /> <br /> OOMMEMTS AND CObD[TION. <br /> <br /> 1. TNIS SEPTIC REVIEW WAS COMPLETED BY LEE .A. GRIMES ON OCT. <br /> ],~5,, SPACE tS LIMITED FOR REPAIRS. INSTALL AS MUCH DRAIN- <br /> FIELD AS POSSIBLE. 225 FEET FOR A ~ULL ~DE REPAIR.' MUST <br /> PUMP AN~ PROPERLY ABANDON THE, ~EXZ~TIbG' SEPTIC TAN(. SUBMIT <br /> PUMPING REOEIPT AND COMPLETED~ABANBONMENT. FORM TO OUR OFF'ICE <br /> TAX LOTS SHOULD BE COMBINED 8S PROPOSEI) ~EPAIE WILL CROSS <br /> LOT LINES. THI~ IS THE REPAIR SO NO NEED ~0 RESERVE SPACE <br /> FOR FUTURE REPAIRS. REFER TO SITE PLAN DATED' <br /> 2. The site p~us~ be protected fro~ trafffc~ livestock~ farthing <br /> or other da~lagin~ activities.: <br /> <br /> <br />