Laserfiche WebLink
./ <br /> <br />MARION COUNTY BUILDING INSPECTION <br /> COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 · Phone; (503) 588-5147 · 24-HR Inspection Line; (503) 588-7904 <br /> <br /> AUTHDRIZATIOM/HAJOR REPAIR PERHIT <br />~ATE/TIHE : 88/24/95 87:4~ STATUS : ISSUED <br />PERHIT HO : 75-158~ APPLIED : ~8/18/17~5 <br />: TYPE : SP ISSUED : 88/24/I795 <br />CLASS : TO EXPIRE : 88/25/1976 <br />:OCCUPAHCY : R~3 PA~E 2 <br /> <br /> AUTHORIZATION/MAJOR REPAIR PERMTT <br /> <br />Th:is Authorization Hot'ice is for an inspection of ~he exis'tinq septic SYStem ~ervinq a RESIDEN'[IAL. <br />buildinQ. AI~ inspection of the system has determined that tb~ system i~s failing a~O in ~eed of <br />repair. B~sed or~ ~be results of ~het inspec'tion.~ the system is ¥1ot appreved fo~~ t['l~ use proposed <br />in your application. Site approval has been gra~ted amd '~he propert'y is approved for the <br />ins~'l:all~ion of ~ new system. This approval [~ site specific and MtS~ be inst~lled accordin~j to <br />the fo[lowing specifica~ionm and the attaqhed mite plar~. ' <br /> <br />Soils in the approved area shall not be alter-ed or Modif~ied by cutting, fillir~q~ or ether <br />activities which would impede the successful operation of the septic system. ODserve ali. <br />required setback/separation dis"~a~aces during ~he installation of the system. <br />Keep this document with your records. Give a copy of thim perl,~it to the septic system <br />la, taller prior to the installation of ~he'sys~eM. Any devimtio~ from the appreved plan <br />Must have prior approval from ~his offi:e. <br /> <br />The following constroctio~ specificatiom~ shall apply to the inst'ellat'io~t of the septic sys'te~q:; <br /> TYPE OF REPLACEMENT ~YSTEH: STANDARD <br /> MINIMUM SEPTIC TANK CAPACITY:I~8 ~ALLONS <br /> LINEAL FEET OF DRAINFIELD: 45~ <br /> TYPE OF D~:STRIBUTION: SERIAL <br /> DISPOSAL TRENCH DEPTH: 24 INCNES, MINIMUM;24 INCHES, MAXIMUM <br /> TQIAL. DRAIN MEDIA DEPTH: 12 INCHES <br /> DRAIH MEDIA UNDER PIPE: 8 INCHES <br /> MINIMUM SOIL BACKFILl.: 12 INCHES <br /> GROUHD WATER INTERCEPTOR: N <br /> <br /> The dJ. sposal ~"e~cl~es are constructed '~wo (2) feet wide and on elin~muM ten (1~) fool <br /> centers. Thee trenches and pipe ere installed level (+/- one inch) from the box '~o <br /> the end of '~he tre¥~ch and contoured to follow the natural ground surface. <br /> <br />2. <br /> <br />4. <br /> <br /> COMMENTS AND CONDITIONS <br /> <br />I'H~S SEPTIC REVIEW WAS COMPLETED BY LEE. A. GRIMES ON AUGUST <br />14~ 1~95. THIS REVIEW ~$ PO~ A MAJOR SEPTIC SYSTEM <br />TO ~EPLACE TNE SEPTIC TANK AND DRAINFIELD. <br />The a$~acbed. O~ANGg ~AR~ MUSt be posted at' the cou~ff:y read. <br />Th~ si'ce m~ts~ De pro~ec~md from ~rsffic~ live~o~k,~ farming <br />or other da~agi~o <br />Install ~he o~w 8rai~fi~)~ withzM the immediate area of the <br />test pits. Soil co~di~io~s are marginal for a st~dard re- <br />system drain~i~ld. Use care not to'alter the natural topsoil <br />witl~in 'Ohm dralofield'si~e ~rior to .iostalIatioo. An ef'flu- <br />?~ pu~p will be ~ecessary 'Bo i.ns'ta~~ tbe drai~field within <br />l:ne approved area at ~he tort'eot deptb. <br /> <br /> <br />