My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1298314
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
95-XXXXX
>
Permit - 1298314
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2011 8:15:47 AM
Creation date
9/4/2003 2:08:12 PM
Metadata
Fields
Template:
Permits
Permit Address
14323 STENBOCK WY NE
Permit City
Aurora
Permit Number
555-95-17885
Parcel Number
041W02D 00602
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE: <br /> <br />Al)DRESS: 22785 Airport Rd. NE, Aurora <br /> <br />FACILITY NAME: Cotmnbia Aviation Assoc. Club ~ouse <br /> <br />BUILDING PERMIT NUMBER: 95-17885 <br /> <br />OFFICE OF STATE FIRE MARSHAL <br /> Oregon State Police <br /> <br />The project mentioned herein has been reviewed for conformity with tim requirements of the Uniform Fire Code, <br />1991 Edition as amended and adopted by be State of O!egou, Office of State Fire Marshal. NOTE; This review <br />shall not substitute for fire and life safety plan reviews as required by ORS Chapter 455 and specified in the <br />Uniform Building Cede, 1991 Edition, Section 302. <br /> <br />Water supply shall comply with UFC 10.401. Specifically, the required water supply for this building requires <br />a minimum of 30,090 gallons ba~d on NFPA 1231 !(P~staurant, 5; wood f~:aw, e construction, 1.5; building <br />volume, 100,300 fi~; no exposures within $0 feet). Thc required fire flow must be no less than 1000 gallons <br />per minute, UFC 10,401 <br /> <br />2. Based on building location in relation to the property lines, all ex, error walls and openings shall be in <br /> accordance with L~C 504Co). Portions of the exterior walls i~ the social space (room 108) and the Icunge <br /> (room 109) must be constructed to 1 hour fire n~sisti~e construction standards. Portions of the lounge (room <br /> 109) exterior walls require openings to be protected by 45 minute fire rated assemblies. UFC 10.601, 10.602 <br /> <br />3. Based on the assembly areas shown without fixed seating, posting of the maximum occupant load shall be in <br /> accordance with UBC 3302(e) for the dining room (tOOth 112), social space (room 108), and lounge (room <br /> 109). Maximum occupant loads are as follows; Dining Room- 128 (less concentrated), 275 (concentrated); <br /> Social Space- 64 (less concentrated), 137 (concentrated); Lounge- 27 (less concentrated), 5g (concentrated). <br /> Contact 'he State Fire Maxshal for posting $igt~. UFC 25,114 <br /> <br />6. <br /> <br />7. <br /> <br />8. <br /> <br />Provide panic hardware to all exit doors in accordance with UBC 3317(d). This includes doors 1, 7, g 9 and <br />10. Door number I (main entrance) may have locking hardware in lieu of panic hardware in accordance with <br />LFBC 3317(d) Exception. UFC 25.106 <br /> <br />Provide exits signs at all exit doors in accordance wilh UBC 3314 including doors 1, 7, 8, 9, and 10. UFC <br />25.113 <br /> <br />Provide emergency exit illumination in accordance with UBC 3313 for the dining room (room 112), social <br />space (room 108), and lounge (rOom 109). DFC 25.113 <br /> <br />Fire exl~ngnishers with a minimum rating of 2A 10BI C shall be installed at the following locations; neat door <br />l and door 10, and in the area near door 17 accessible Rom the social space, UFC 10.505(a) <br /> <br />As submitted, plans do not indicate ffcommcrcial co&king equipment is to be installed in the kitchen (room <br />116). If this condition is present, provide a Type I ventilating hood and duct system in accordance with UMC <br />2003(a) with an automatic fire e.0rtinguishing ~stem lin accordance with UMC 2004(b). In addition, provide a <br />portable fin~ extinguisher with a miniranm rating of {0B C near the kitchen.exit door (door 13). UFC 10.512, <br />10.513(a), 10.513(d) <br /> <br />Plans indicate a fire alarm system to be installed. Fire alarm systelns and devices shall be designed and <br />installed in accordance w/th UFC Article 14. Plans shall be subruitted for r~view prior to installatim~. UFC <br />14.103(a) <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.