My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12986249
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
12-XXXXX
>
12986249
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 8:00:11 PM
Creation date
7/30/2025 9:43:53 AM
Metadata
Fields
Template:
Permits
Permit Address
6203 SHAW LN SE
Permit City
Aumsville
Permit Number
555-12-05259
Parcel Number
082W24A 00800
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
k. ..en . _... -.- Page 1 <br /> W• arren'Jackson -B1215 Screen Gnd Test 002.�pg .._. <br /> • <br /> Par}ral T2e,0.0. <br /> wall in the windward side is quite pronounced,with the separation of a conical crack in the <br /> concrete in the wall base and vertical cracks along the bar.A vertical splitting crack also <br /> developed on the east side of the windward toe. <br /> From the data collected,the global shear stiffness of the panel was calculated using Eq.2.The <br /> global shear stiffness(G')was calculated to be 70S,000 lb/in.for a 5,000 lb lateral load level and <br /> 308,500 lb/in.for an 8,500 lb lateral load level. <br /> WALL PANEL 4,ICF SCREEN-GRID WALL PANEL • <br /> Wall Panel 4 was an ICF screen-grid panel.The forms for this specimen were provided by <br /> Reddi-Form,Inc.Figure 34 shows the forms used for casting.This wall panel wits designed for <br /> wind speed of up to 70 miles per hour according to the Prescriptive Method for Insulating <br /> Concrete Forms in Residential Construction. <br /> Structural Details <br /> Figure 35 shows the structural details of Wall Panel 4.This drawing depicts the dimensions and <br /> reinforcing details of the concrete panel and does not show the insulating concrete forms.The <br /> concrete wall panel consisted of a monolithic network of five vertical ties(columns)and seven <br /> full,plus two one-half horizontal ties(beams).The 6x8-in.beam on the top of the panel was for <br /> distribution of the lateral in-plane load and did not constitute a structural part of the wall.This <br /> wall panel was cast on an 84x18x14-in.reinforced concrete footing,with details shown in Fig. <br /> 28.Mechanical properties of concrete and reinforcing bars were as described for Wall Panel 3. <br /> The top surface of the footing was roughened and cleaned before casting of the wall to provide <br /> better friction and bond.According to the cold joint requirements of the Prescriptive Method <br /> cited above,three No.4 dowels connected the wall to the footing.The wall panel had three <br /> horizontal bars,one on top and two others at about the1/3 and 2/3 points along the height. <br /> Standard hooks were provided at the ends of the horizontal bars.This was to simulate,as much <br /> as possible,the continuity of the horizontal bars as required.In Ibis wall panel,no vertical <br /> reinforcing bar was used.However,three dowels similar to those in the footing were inserted <br /> between the wall panel and the top beam.A 6x6x1/4-in.plate was anchored to the side of the top <br /> beam to be used for application of the load and bearing of the load cell. <br /> • <br /> ilbre <br />
The URL can be used to link to this page
Your browser does not support the video tag.