® WESTERN ELECTRO - ACOUSTIC LABORATORY, INC. • <br /> TESTING • CALIBRATION • RESEARCH • CONSULTING j 1711 Sixteenth Street, Santa Monica, California 90404 (310) 450-1733 Fax: (310) 396-3424 <br /> REPORT 30 March 1999 <br /> SOUND ABSORPTION TEST NO.AB99-142 <br /> CLIENT: K-X INDUSTRIES,INC. <br /> TEST DATE: 29 March 1999 <br /> TEST SPECIMEN: Free Standing Wall Specimen <br /> INTRODUCTION • <br /> The methods and procedures used for this test conform to the provisions and requirements of ASTM Procedure <br /> C423-90a,Standard Test Methadfar Sound Absorption and SaudAbsorption Coefficients by the Reverberation <br /> Room Method. Details of the procedure will be burnished upon request. Western Electro-Acoustic Laboratory is <br /> accredited by the United States Department of Commerce,National Institute of Standards and Technology under the <br /> National Voluntary Accreditation Program(NVLAP)for this test procedure. This test report relates only to the <br /> item(s)tested. Any advertising which utilizes this test report or test data must not imply product certification or <br /> endorsement by WPM,NVLAP,NIST or the U.S. Government. <br /> DESCRIPTION OF TEST SPECIMEN <br /> The test panel was a K-X Industries free standing wall section. The mart l cturer's description of the specimen was <br /> as follows: <br /> The FASWALL insulating permanent concrete forms(ICF)were manufactured in a block making machine <br /> using the K-X mineral processed wood fiber chips(K-X Aggregate)mixed with cement and fly ash. The wall J <br /> forms(WF)had male-female interlocking sections on the sides. <br /> The specimen was constructed in the laboratory on a reinforced pallet to allow installation and removal from <br /> the test chamber. The wall forms(WF)were stacked dry without staggering them and no mortar was used. <br /> The WF were filled with dense concrete that was mixed in a concrete mixer and poured into the cores with <br /> buckets. The concrete was allowed to cure for approximately 72 hours before testing. The overall dimensions <br /> of the sample were 48 inches(1.22 m)wide by 72.5 inches(1.84 in)high by 11.5 inches(.292 m)thick. The <br /> area used in the calculation included both sides,both ends, and the top of the specimen. All gaps and spaces in <br /> the pallet wereTdled with concrete and 2"x 6"wood studs were used around the perimeter of the pallet to seal <br /> it to the floor of the chamber. The overall weight of the specimen was estimated to be 1885 lbs. (855 kg)based <br /> on 781bs./ft2(1249 kg/rnr). <br /> TEST RESULTS <br /> Area Tested: 59.91 sq.& Mounting:Free Standing <br /> 1/3 Octave Band Center Frequency(Hz) <br /> 125 250 500 1000 2000 4000 NRC <br /> Sound Absorption(Sabin) 15.7 23.2 45.9 55.9 52.7 55.1 <br /> Sound Absorption Coefficient .26 .39 .77 .93 .88 . .92 .70 <br /> 95%Confidence .08 .05 .07 .06 .04 .04 <br /> Respectfully submitted, <br /> Western Electro-Acoustic Laboratory,Inc. <br /> iffitn <br /> nang <br /> Gary E. e <br /> /.CCREOREO Sv TAR LA00 LixsrllVTE OF 6T WAos RkMlFOR SEL CTED TES -� <br /> Ifs. �V%UUL=J r�fJ =ND VCLNNTpilytx, pTOflYRCCR g,TDONars AND WR SELECIERTEST METgp$Fgp ACOUSTICS <br />