Laserfiche WebLink
Warren Jackson -Faswall Alt 004.jpg Page 1 <br /> Fc,s Wall C"n4 <br /> 4) Sound Transmission test per ASTM E90-97 and E413-87 by"Riverbank Acoustical <br /> laboratories",1512 Batavia Ave.,Geneva,Illinois(3 pgs) See report for lab accreditation. <br /> The concrete wall reduces noise very well. <br /> Sound Absorption,ASTM C423-90a by"Western Electro Acoustic Laboratory,Inc., 1711 <br /> Sixteenth St.,Santa Monica,CA(1 pg) <br /> 5) Rapid Freeze Thaw ASTM C666—84 by"Construction Technology Laboratories"5420 Old <br /> Orchard Rd.,Skokie,Illinois.(2 pgs)Accredited,ISA,ISO/IEC 17025. www.ctivoun.com. The <br /> sample of Faswall showed no significant change/damage until after 233 cycles. Therefore fairly <br /> resistant to freeze thaw damage. <br /> 6) Insect/termite resistance,University of Georgia,Collage of Agriculture and Environmental <br /> Sciences.(1 pg)413 Biological Sciences Building,Athens,Georgia <br /> The Faswall material is very resistant to termite infestation. <br /> Other than the University study the testing labs are accredited labs. <br /> The last pages are the old ICC report,ignore as you see fit. <br /> Yes,the testing was conducted under older ASTM but to be seen as at least equivalent to wood <br /> code framing for home construction,if the Faswall material did not burn then(given a 4 hour <br /> rating)and termites will not damage it,then it will not burn now. <br /> We have rim numerous analyses comparing a solid wall to the screen wall layout for a reinforced <br /> concrete wall. The use of an R of 3.5 is much less than an R of 5 fora"Special reinforced <br /> concrete shear wall"provides for an added measure of conservative load forces. Our shear wall <br /> design follows ACI 318 in regards to special reinforced design procedures. The ICF block itself <br /> is only a form as with any other ICF product. The concrete screen wall system is also stiffer than <br /> and has more redundancy than a"Concrete Moment Frame"design. The connecting webs are <br /> only an average of 3 inches long and spaced every 16 inches vertically. For many shear wall <br /> section the double notch blocks are specified resulting in horizontal webs at 8 inches on center. <br /> See the attached pages that ran test on unreinforced walls with horizontal cells 12 inches on <br /> center. Test case by Armin B.Meluabi. The test wall failure is a typical diagonal shear crack as <br /> would be expected from even a solid shear wall design and construction. <br /> The use of an R of 3.5. The screen wall is a small bit of both systems a solid wall and moments <br /> frames. An average of the two systems would result in an R of 3.5. 1 have been designing with <br /> an R—3.5 as I have done several houses since designing the in CA,OR,WA as well as CO and <br /> OK. The It is also dependant on what seismic design Category the project may be placed in and <br /> should be verified by the design Engineer of Record. In seismic Category D end above ordinary <br /> concrete is typically not allowed. Our design follows ACI chapter 21 for the"Special Reinforced <br /> Concrete"to allow projects to be placed in areas of Seismic Design Category D. Testing on a <br />