My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1298661
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 3
>
Permit - 1298661
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2011 10:20:09 AM
Creation date
9/4/2003 2:18:30 PM
Metadata
Fields
Template:
Permits
Permit Address
44125 NORTH SANTIAM HY SE
Permit City
Detroit
Parcel Number
105E 00100
Permit Type
Permit
Permit Site Number
2518
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 2 <br />Burby <br /> <br />3. On sheet SIO: <br /> <br />I cannot determine any benefits in providing bedding materia] <br />and crushed rock along side of, above, or to the ground surface <br />in the building sewer trenches, effluent sewer trenches, main <br />and secondary pressure transport trenches, and pressure manifold <br />trenches, During heavy rainfall or snow melt periods, I would <br />expect surface and soil waters to be collected and flow in <br />these, if constructed as designed, Since the disposal field is <br />at the "end of the llne", you cOUld flood it out. I would <br />simply bed only the bottoms of the pipes and fill the remainder <br />of the trenches with backfilled soils, I would not use any <br />bedding on the pressure transport pipes; this is particularly <br />important on the pressure manifold portions of your system. <br /> <br />Do not excavate a conmon trench down through the disposal fields <br />to ~ the pressure manifold pipes. If you do, all effluent <br />will flow down to the bottom lines and flood them ou~. ) would <br />reco~end hand digging narrow trenches for this portion of the <br />system, and not having them any deeper than is necessary for a <br />connection to the individual pressure distribution laterals. On <br />a sloping hillside, you want an undisturbed earthen barrier <br />maintained between individual lateralS, SO effluent from one <br />line cannot short circuit into a lower line. <br /> <br />On the individual disposal field pressure distribution laterals; <br />they need to have a filter material that ranges in size from <br />l~1/2 to 2-1/2 inches. There must be a minimum of 12 inches of <br />backfilled soils. Do not extend the filter material to the <br />ground surface as show~ in the plans, (or you'll be sorry!). <br /> <br />The diagram of the two compartment septic tank appears <br />reversed. The inlet compartment needs to be 2/3 the size of the <br />total volume, The outlet fitting from the first compartment to <br />the second compart~nt also needs to be reversed; otherwise, it <br />will pick up sludge accumulations from the first compartment. <br /> <br />1/8 inch opening screens are definitely necessary, either in the <br />tanks or in the dosing chamber, prior to the dosing siphons, <br />The screens should have a minimum of twelve IlS) square feet of <br />surface area. <br /> <br />4. On sheet Slt: <br /> <br />The dosin9 tank needs to be provided with a manhole access ~ha~ <br />has the following minimum horizontal dimensions; <br />1. Opening at tank soffit - 30 inches. <br />2. Inside of manway - 42 inches. <br /> <br /> <br />