TFP370 <br /> Page 2 of 12 <br /> tir SYSTEM PIPING WITH ULTRA KIT AUTOMATIC SPRINKLERS <br /> t \ t t t t t <br /> DIAPHRAGM LOW AIR <br /> FIRE DETECTION CHAMBER MODEL <br /> (PREACTION ONLY) PRESSURE ORS SYSTEM <br /> GAUGE SWITCH AUTOMATIC SHUT-OFF VALVE <br /> DRY AIR (SUPERVISED. <br /> II N SUPPLY NORMALLY <br /> T OPEN) <br /> SOLENOID \ ` <br /> VALVE <br /> RELEASING MODEL <br /> PANEL ^' SYSTEM MAIN RISER CHECK <br /> (AUTOMATIC DRNNVALVE —f VALVE <br /> CONTROL UNIT DRAIN (NORMALLY <br /> WITH BATTERY MODEL ASV-1 CLOSED) <br /> BACK-UP) LOCAL AUTOMATIC [dfAdN -- WATERFLOW <br /> HYDRAULIC SHUT-OFF VALVE PRESSURE <br /> -----_ , MANUAL w/RESTRICTION - ALARM SWITCH <br /> I I CONTROL <br /> STATION �_ -- DV-5 <br /> I MI DELUGE VALVE <br /> � <br /> I MANUAL MAIN DRAIN VALVE � <br /> ELECTRICAL DRAIN (NORMALLY CLOSED) DRAIN WATER SUPPLY <br /> PRIMARY PRESSURE <br /> POWER PULL STARON GAUGE <br /> SUPPLY (AS REQUIRED) DIAPHRAGM CHAMBER <br /> _ SUPPLY CONNECTION MAIN <br /> DIAPHRAGM CHAMBER- i CONTROL VALVE <br /> SUPPLY CONTROL VALVE I (SUPERVISED <br /> (NORMALLY OPEN) WATER NORMALLY <br /> SUPPLY OPEN) <br /> 'I FIGURE 1 <br /> QUELL SYSTEM PIPING SCHEMATIC <br /> One of the best alternatives for elimi- Features NOTICE <br /> noting in-rack sprinklers has been the • Eliminates in-rack sprinklers for The QUELL Preaction and Dry Systems <br /> installation of an Early Suppression refrigerated and cold storage described herein must be installed <br /> Fast Response(ESFR)sprinkler system; • An innovative approach to addressing and maintained in compliance with <br /> however, due to its(Imitation of being a high-challenge fire hazard that this document and with the appli- <br /> a wet pipe sprinkler system,the ESFR departs from previous control mode cable standards of the National Fire <br /> System is limited to installations at or and suppression mode approaches Protection Association (NFPA), in <br /> above 40°F(4°C).Now,with the QUELL addition to the standards of any author- <br /> System SprinkFDT-Q Fluid Delivery • Eliminates the need for care intensive ities having jurisdiction.Failure to do so <br /> Calculation Program and Model ORS anti-freeze system may impair the performance of these <br /> Electronic Accelerator technology, • Fully pre-engineered riser devices.Applicable Standards are: <br /> there is an alternative for protecting <br /> refrigerated and cold storage without • Fully supervised riser with dedicated • NFPA 13,Edition 2013 <br /> the need for in-rack sprinklers (Ref. control panel • NFPA 20, Edition 2013 <br /> Tables A,B,and C). • Built-in electronic accelerator to opti- • NFPA 24, Edition 2013 <br /> Applications for the QUELL Preaction mize water delivery time • NFPA 25,Edition 2014 <br /> and Dry Systems are expanding beyond • Selection of system air pressure is <br /> the currently approved hydraulic design independent of water supply to opti- <br /> and • NFPA 72,Edition 2013 <br /> water delivery criteria.For informa- mize water delivery time The owner is responsible for main- <br /> tion regarding research fire tests which Paining their fire protection system and <br /> may be acceptable to an authority • Trip testing without flooding system devices in proper operating condition. <br /> having jurisdiction, please contact • Remote signal contacts Contact the installing contractor <br /> TFPP Technical Services. or product manufacturer with any <br /> • Fully assembled preaction cabinet questions. <br />