Template:
Permits
Permit Address
3630 KASHMIR WAY SE
Permit City
Salem
Permit Number
555-16-007711-STR
Parcel Number
082W18B 01700
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Drawing No. Rev. <br /> ENGINEERING JUDGMENT FIRESTOP DETAIL NS3O516OO5 A <br /> 'F Rating-3 HR <br /> a <br /> •ge. <br /> „,,, <br /> CO <br /> 4.0 <br /> 1. Roof Assembly(Non Fire Rated)-Non-rated roof decking consisting of steel roof panels over steel purlins. <br /> 2. Wall Assembly (3 Hr)-Gypsum board/steel stud wall assembly(UL U,V or W400 Series Design). Additional <br /> framing members installed to frame openings around steel purlins. Gypsum board cut to the contour of the steel <br /> purlins. Joint width between top of gypsum board and bottom of roof deck is max 1". Clearance between gypsum <br /> board and purlins is min 1/4"to max 3/4". <br /> 3. Packing Material(Not Shown)-Where flutes are present, min 4 pcf mineral wool batt insulation compressed <br /> 14% and installed into flutes to full depth, recessed from both sides of wall to accommodate for sealant. <br /> 4. Sealant-SpecSeal®ES or LCI Sealant applied into flutes(when present),joint and notched opening to a min <br /> 1°thickness,flush with both sides of wall. <br /> *Note: 1 -Rating of the firestop system is dependent on the performance of the surrounding construction under <br /> —_-fire-exposure with a maximum possible F Rating of 3 Hr. 2-System is designed to be static. 3 -T rating may not <br /> equal F rating per UL2079. <br /> THIS DESIGN REPRESENTS A FIRESTOP SYSTEM EXPECTED TO PASS THE STATED RATINGS IF TESTED <br /> Protect. Beggs Construction Building_Pat Beggs Construction Signature: System Reference <br /> ^ C-JD-0002, HW-D-0491, <br /> Rmren Aderesa:Salem, OR 97301 HW-D-0041 <br /> Designed by'.Joe Pans W CMS <br /> Contractor.Pat Beggs Scale: Date. Base°on testing b ASTM Eatamc Ins standard for Fire <br /> 99 _ - N.T.S. 11/30/2016 PAGE I OFI Tests of Perelratom aiaabgs <br /> Inc. All statements,technical information,and recommendations contairrea herein are based <br /> Specified TechnologiesW upon tests we believe to be acetate however since the conditions of use and application <br /> are beyond our control,STI shall not be liable for any damage.direct or consequential. <br /> M111 rim Way4one.,kJ YA tY•TM rw:WCEn11W11 VI H.94100. resulting from the use of this material or design.STya sole warranty shall be to refund or <br /> . P.M IO. IN10•E:behrive•Whobpseen•wifitffinstellaa replace materials found to be defective. <br />