Laserfiche WebLink
SPECIFICATIONS I FIG.3:HEAD-OF-WALL JOIN - GYPSUM WALLBOARD WALL TO CONCRETE FLOOR <br /> The fire protective sealant shall be a water- Assembly <br /> based, non-halogenated, elastomeric and <br /> shall contain no solvents, inorganic fibers, J <br /> nor asbestos. The sealant shall dry to form Elastomedc _ r1 <br /> a flexible, moisture resistant seal and shall Sealant rl�� <br /> adhere 10 all common construction surfaces. • <br /> The sealant shall have demonstrated sound <br /> attentuation properties.The approved sealant s Gypsum <br /> desshall be SpecSealw Elastomeric Sealant. n Wallboard <br /> SPECIFIED DIVISIONS 1' Assembly <br /> DIV.7-0784 00 Firestopping UL System No.HW-D0079 <br /> DIV.7—078443 Fire Resistant Joint Sealants Assembly Rating-1 8,2 Hr•Movement Capabilities:25%Compress. <br /> Nominal Joint Width:3t4 •Forming Material:In 1 hr walls,apply bond breaker tape to ceiling track. <br /> INSTRUCTIONS Sealant Depth:6/6-depth on both sides. <br /> GENERAL:Areas to he protected must be clean and <br /> free of oil,loose dirt rust or scale. Recommended jPic.4:HEAD-OF-WALL JOINT-GYPSUM WALLBOARD WALL CUT TO FIT CONTOURS OF <br /> STEEL DECK <br /> storage and applicationtemperatures range between <br /> 40°F(4°O)and 95°F(35°C). When applying product Steel Deck <br /> at the lower end of the temperature range,warming Assembly <br /> • <br /> the material to 70°F (21°C)will enhance drying <br /> Elastomeric --- <br /> characteristics. Drying time will vary according Sealant <br /> to prevailing temperature and humidity. Allow to <br /> thoroughly dry before exposure to moisture. <br /> Consult appropriate manufacturer's drawing for • o <br /> Gypsum <br /> system design requirements. Forming or packing Wallboard <br /> materials may be required as an integral part of Assembly <br /> various system designs.See Table B for estimation <br /> information. Backer Rod <br /> Sealant is auto-bonding and may be applied in UL System No.HWo-0103 <br /> stages. DO NOT ATTEMPT TO THIN PRODUCT Assembly Rating-182Hr•MovenentCepabiliiies:25%Compress. <br /> BY ADDING WATER. Nominal Joint Width:3/4"•Forming Matedal:In 1 hr walls,apply band breaker tape to ceiling track. <br /> Sealant Depth:1/2"depth on both sides. <br /> THIS PRODUCT IS DESIGNED FOR <br /> PROFESSIONAL INSTALLATION ONLY. This FIG.5:HEAD-OF-WALL JOINT-GYPSUM WALLBOARD WALL TO CONCRETE OVER STEEL <br /> sealant is designed to contract while drying,Proper DECK <br /> pint design is critical to sealant performance.Avoid Steel Deck <br /> three point adhesion through the use of appropriate Assembly <br /> backing or bond-breaking materials. _ - <br /> See Figure 2 for recommended joint designs, Elastomerc Q <br /> Consult ASTM C1193 Standard Guide for Use of Sealant - '—i <br /> Joint Sealants for additional guidelines concerning <br /> amproper appacatlon of sealant materials. <br /> f Gypsum, al ad <br /> Assembly Inspection: Installations should be inspected <br /> Mineral <br /> periodically for subsequent damage. Following Wool <br /> safety precautions listed in Precautionary Information UL System No.NW-D-0034 <br /> Assembly Rating-18 2 Hr•Movement CapabIiUes:25%CompresslEmend. <br /> and pertinent installation guidelines,remove coating Nominal Joint Width:1"•Forming Material:Nom 4 pet mineral wool to lull depth. <br /> Sealant Depth:12"depth on both sides. <br /> in damaged areas down to undamaged material. <br /> �y Reapply fresh coating material to original coating <br /> thickness. _Y <br /> 2 STI Maid Data Sheet• ES Elostamerir Sealant • F00-5032 2506 Technical Service 1-800-992-1180 <br /> www.sufirestop.com STI. <br />