My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13000296
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
14-XXXXXX
>
13000296
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2025 8:00:12 PM
Creation date
8/4/2025 4:42:51 PM
Metadata
Fields
Template:
Permits
Permit Address
3205 DEER LAKE CT SE
Permit City
Salem
Permit Number
555-14-001595-DWL
Parcel Number
083W25A 01600
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
p.12 <br /> FIRE AND SMOKE PROTECTION FEATURES <br /> • <br /> L. 715.4.7.2 Exit and elevator protecdves. Approved <br /> fir 1. Doors installed across accrr.Cer. <br /> �/ e-protection-rated glazing used door assemblies 2. Doors that protect openings in exits or corridors <br /> iu elevator and eat enclosures shall be so located as to rewired to be of Ere-resistance-rated consiruc- <br /> funiisli clear vision of the passageway or approach to the tiro <br /> elevator,ramp or stairway <br /> 775.4.7.3 Labeling.Fire -rated 3a+�n shah 3. Doers that protect openings in walls that are <br /> g P g £ capahle of resisting the passage of smoke in <br /> bear a label or other identification showing the name of accordance with Section 508 2.5.2. <br /> the manufacturer, the test standard and information . <br /> required in Section 715.5.9.1 that shall be isaned by,an 4. Doors installed in smoke bathers in accordance <br /> approved agency and shall be permanently affixed to the with Section 710,5. - <br /> glazing. 5. Doors installed in fire partiflans in accordance <br /> 715.4.7.3.1 Identification.For fie protection-rated withSection 709.6. <br /> gluing,the label shall bear the following four-part 6. Doors installed in afire wall in accordance with <br /> identification:"D—H or NH—T orNT—XXX."'D" Section 706.8. <br /> indicates that the glazing shall be used in fire door 7. Doors installed in shaft enclosures in accordance <br /> assemblies and that the glazing meets the fire protec- with Section 708.7. . <br /> tion requirements of NFPA 252. "H" shall indicate t <br /> that theg]asingmrlc die hosesteamregit¢emenci of 8. Doors installed in refuse and laundry chutes and <br /> NFPA 252."NA"shall indicate that the glazing does . mates end terminatiouroornsin accordance with <br /> not meet thehcsestream requirements of the test.'T' Section708.13. • <br /> shall indicate that the glazing meets the tenipenturo 9. Doors installed in the walls for compartmentaticn <br /> requirements of Section 715.4.4.1. "NT' shall iadi- of underground bail dings in accordance with Sec- <br /> satethat the glazing does not meet the temperature bon 405.4,2. <br /> recuirements of Section 715.4,4.1. The placeholder 10. Doors installed in the elevator lobbywalls of <br /> "XOC" shall specify the fire-protection-rating <br /> underground buildings in accordance with Sec- <br /> percd,in minutes. <br /> Don 435.43. <br /> 715.4.7.4 Safety glazing.Fire-protection-rated glazing 11. Doors mstalledinsmokepzniboos in accordance <br /> (be . .installeidjpfvz doors in areas subject to human impactin <br /> azc:dous Iocaflons shall comply with Chapter 24. With Section 711.5.3. <br /> -'-""�r�,-_ 715.4.8.4 Doors in pedestrian ways.Vertical sliding or <br /> I�715,4-8 Door closing.Fite dooms e - vertical rolling steel fire doors in openings through <br /> {matic-dosing in accordance with this section, w}ych pedestzians travel shall be heat activated or acti- <br /> ifll Exceptions; vated by smoke detectors with alarm verification. <br /> 1. Fire doors 1n�a:rY in noatman wells separating 715.4,9 Swinging fire shutters.Where fire shutters of the <br /> ' i sleeping units in Group R-1 shall be permitted swingingopenings, <br /> Tjpe are installed in exterior o .nmgs, not less <br /> without automatic-or self-closing devices, than onerewm every three vertical rows shaibearranged to <br /> i 2. The-elevator car doors and the associated hoistway be readily opened Cmmthe outside,and shall be identified} enclosuie doors at the fioot level designated for by distinguishing marts or'leaers not less than 6 Mches(132 <br /> i recall in accordance with Section 30032 shall be sin)high. <br /> petaniried to remaic open during Phase I emer- 715.4.10 Rolling fire shutters.Where fie shutters of the <br /> \gency recall operation_ rolling type are installed, such shutters shall include <br /> 7i5.4.8.11W—iregnire . nlesset envisesp' cmcaly approved automatic-closing devices. <br /> pemtiGed, single tire doors and both leaves of pairs of 7155 Fire-protection-rated glazing. Glazing infra window <br /> side-hinged swinging fire doors shall be provided with assemblies shall be fire-protection rated in accordance with this <br /> an active latch bolt that will secure the door when it is sezdcn and Table 715.5,Glazing in fire door assemblies shall <br /> closed. . comply with Section 7]5,47.Fim-protection-rated glazing shall <br /> be tested in accordance with and shall meet the acceptance mite-715.4.82 Automatic-closing 5re door assemblies. riaofNFPA 257 orUL 9.Puo-protection-rated easing shall also <br /> Automatic-closing fire door assemblies shall be comply with NFPA 80. Openings in cormr-resistance-rated <br /> self-closing in accordance with NFPA 80. ezzerior meal/assemblies that. uir^protection in accordance <br /> require <br /> 7I5.4.3.3 Smoke-activated doors.-Automatio-closing with Section 705.3, 705.S, 705.3.5 or 705.3.6 shall have a <br /> doors installed in the following locations shall be aura- fire-protection rating of not less than114 hour. <br /> matic-dosing by the actuation of smoke detectors Exceptions: <br /> installed in accordance with Section 907.3 or by loss of <br /> ' power to the smoke detector or hold-open device.Doors I. Wired glees in accordance with Section 715.54. <br /> that are automatic-closing by smoke detection shall not 2. Fire protection-rated glazing in. 05-hour fire-resis- <br /> tance-ratedthestarts partitions is permitted to have as <br /> to close after the smoke detector is acmated: 0.33-hour fire-pr*cdon rating. <br /> 122 • 2010 OREGON STRUCTURAL SPECIALTY CODE <br />
The URL can be used to link to this page
Your browser does not support the video tag.