Laserfiche WebLink
Intertek 130 Derry 17Court <br /> York,Pennsylvania ll406 <br /> Total Quality.Assured. Telephone: 717-764-7700 <br /> Facsimile: 717-764-4129 <br /> www.intertek.com/building <br /> TEST REPORT FOR EASTMAN PERFORMANCE FILMS, LLC <br /> Report No.: 12316.03-119-37 <br /> Date:03/26/18 <br /> REPORT ISSUED TO <br /> EASTMAN PERFORMANCE FILMS,LLC <br /> 4210 The Great Road <br /> Fieldale,Virginia 24089 <br /> SECTION 1 <br /> SCOPE <br /> Intertek Building & Construction (B&C) was contracted by Eastman Performance Films, LLC - <br /> Fieldale,Virginia to perform safety glazing material performance testing In accordance with ANSI <br /> Z97.1 and CPSC 16 CFR 1201 of their LLumar SCL SR P513 Film on 1/8"thick annealed glass.Results <br /> obtained are tested values and were secured by using the designated test methods.Testing was <br /> conducted at the Intertek B&C test facility in York, Pennsylvania. This report does not constitute <br /> certification of this product nor an opinion or endorsement by this laboratory. <br /> SECTION 2 <br /> SUMMARY OF TEST RESULTS <br /> Film: LLumar SCL SR P513 <br /> Glass: 1/8" annealed glass <br /> Glazing Type:Organic Coated Glass <br /> ix <br /> ANSI Class A 48 in. (1219 mm) Pass <br /> CPSC Category II 48 in.(1219 mm) Pass <br /> 1The performance evaluation of the product identified in this test report was isolated to impact testing only, <br /> accelerated weathering/aging and thermal tests were not performed. <br /> For INTERTEK B&C: <br /> > d *. Todd M.Wilt Virgal T. Mickley,Jr.,P.E. <br /> Lead Technician Senior Stay Engineer <br /> I <br /> $?„ 03/26/18 03/26/18 <br /> TMW:vtm/aaa <br /> This report is for the exclusive use of intertek's Client and is provided pursuant to the agreement between Intertek <br /> and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek <br /> assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or <br /> damage occasioned by the use of this report.only the Client Is authorized to permit copying or distribution of this vi ' <br /> report and then only In Its entirety.Any use of the Intertek name or one of Its marks or the sale or advertisement of pCCRE011ED' <br /> the tested material,product or service must first be approved In writing by Intertek.The observations and test results <br /> In this report are relevant only to the sample(s)tested.This report by Itself does not imply that the material,product, Jets <br /> or service is or has ever been under an Intertek certification program. <br /> Version:08/07/17 Page 2 of 5 RT-R-AMER-Test-2889 <br />