'SI I at"' PACIFIC NORTHWEST INC. <br /> ENGINEERING, <br /> Cornerstone Foundation System LLC July 13, 2018 <br /> 140 Art Mill Lane <br /> Roseburg, OR 97471 <br /> PATENT No. US 9,109,355 BI <br /> Re: Design Criteria Verification <br /> "Smart Foundation" Running Bond 54 (SFRB-54), Ledge Stone 60(SFLS-60), Smooth 60 (SFS- <br /> 60), and "Poured in Place" Footing or "Poured Concrete Runners", Pre-cast Concrete PC-48 <br /> Footing (16" x 48" x 2 Va"), Pre-cast Concrete Masonry Unit Footing (CMU 16" x 16" x 4"), <br /> Composite Board Footing(1 'b"x 6")or Pressure Treated Lumber Footing(2" x 6"). <br /> Dear Norris, <br /> At the request of Cornerstone Foundation System LLC, Pacific Northwest Engineering has reviewed the <br /> empirical testing performed by Cornerstone Foundation System,as witnessed and documented by Umpqua Testing <br /> Services. It is my conclusion the test results and calculations prove that the"Smart Foundation"Rooming Bond 54 <br /> (SFRI3-54), Ledge Stone 60(SFLS-60), Smooth 60(SFS-60),and Pre-cast Concrete PC-48 Footing(16"x 48"x 2 <br /> %x'), Pre-cast Concrete Masonry Unit Footing (CMU 16" x 16" x 4"), Composite Board Footing (I 'G' x 6") or <br /> Pressure Treated Lumber Footing (2" x 6") when used in conjunction with Cornerstone Foundation System is <br /> acceptable as a tie down, perimeter pier and permanent foundation system, with a lateral and vertical force <br /> resisting system for wind zones [, II, and III with a"C"exposure and a seismic design category"DII", Ss=1.384, <br /> Fa=1.0, R=5 lateral load. In addition, an 801b./ Sq. Ft. roof load and up to a 30" lateral soil loads may be resisted <br /> 4 simultaneously. SFRB-54, SFS-60,and SFLS-60 also meet or exceed the design requirements of"poured in place" <br /> or "poured concrete runners" type fowrdation from the "Permanent Foundation Guidebook for manufactured <br /> !lousing"4145.1 Rev. 2 and 4150.1 Rev(1996)and also with the manufacturer pier point layout.The installation <br /> also meets or exceeds the design requirements of the HUD 7584 handbook. This allows the SFRB-54, SFLS-60 <br /> and SFS-60 to meet foundation certification for all HUD, FHA and VA lending on Manufactured Housing <br /> provided that the SFRB-54, SFLS-60 and SFS-60 installation instructions are followed. It also meets or exceeds <br /> the requirements of Section 1333, Chapter 2,Title 25 of the California Administrative Code and 18551 of the <br /> Health and Safety Code. Cornerstone Foundation System meets or exceeds the Oregon 2010 Manufactured <br /> Dwelling Installation Specialty Code and the Model Manufactured Housing Installation Standards. Cornerstone <br /> Foundation System can also be used in flood hazard areas except with composite hoard or pressure treated lumber <br /> footing which allows up to 40 lbs. roof load and 24"soil back fill. <br /> Test results and engineering calculations are available to authorities having jurisdiction when requested. <br /> ov <br /> Additional Information: , . <br /> Contact Person: Norrisa Ahlgren ,C - <br /> Cornerstone Foundation System LLC' ��r ' w" �1 <br /> Phone: (541)733-5441 ' <br /> Email. comerstonefoundationsystem tCi yahoo.com <br /> c WORK CORNERSIONIA3IYx' <br /> 4242 Silver Falls Dr. N.,Silverton,OR.97381 <br /> ph # (503) 873-3184 fax #(503)873-39(17 <br /> P.E. # 13,676 <br /> Page 4 <br />