Laserfiche WebLink
Application Instructions For Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS DS300 <br /> ( E.Application of Backstop NT <br /> ♦/ Note: This section provides the procedure for applying Backstop NT to the wall surface only. At the <br /> completion of the Backstop NT application,all openings and terminations must be treated with either <br /> the Dryvit AquaFlash System or Dryvit Flashing Tape(see Section V)to protect surfaces from water <br /> penetration and all terminations must be otherwise properly flashed to ensure that water is diverted <br /> to the exterior of the cladding. <br /> 1. Dryvit Grid Tape(not required with concrete and masonry substrates.) <br /> a. For sheathing substrates, apply the Dryvit Grid Tape along all joints in the sheathing, as well as inside <br /> corners,outside corners, and exposed edges at terminations that will not be covered with Dryvit <br /> AquaFlash or Dryvit Flashing Tape. <br /> b. Center the Dryvit Grid Tape on the sheathing joints, edges, etc. with the pressure sensitive adhesive <br /> backing in contact with the sheathing surface. Press into position with hand pressure until adhesion is <br /> achieved. <br /> c.Apply only enough Dryvit Grid Tape as can be covered with Backstop NT-Texture in the same day. <br /> 2. Dryvit Backstop NT-Texture Application <br /> NOTE: Backstop NT Texture is NOT recommended for use over the face of OSB. <br /> a. General: Backstop NT-Texture can be applied using a roller,trowel or texture spray equipment over <br /> the listed substrates, as noted in the usage chart above. Backstop NT-Texture should be applied at <br /> the recommended coverage rate to achieve a continuous film at a minimum dry film thickness of <br /> approximately 12 mils(0.3 mm). <br /> b. Roller Application <br /> 1)Apply Dryvit Grid Tape as described in Section IV.E.1 above. Mix the Backstop NT-Texture <br /> material as described in Section I. Using a stainless steel trowel or spatula,apply a layer of <br /> Backstop NT-Texture over the Dryvit Grid Tape and spot all fastener heads—Figure 1. <br /> NOTE: Dryvit Grid Tape is not necessary over fastener heads. <br /> 1/4 (eA m)Max. <br /> Sheathing Joints . <br /> 7e� <br /> a <br /> Backstop NT- <br /> a sk d Tenure <br /> e'3Y„ti4 .e w <br /> Dryvit Grid Tape x t Figures <br /> u <br /> a <br /> u u <br /> 2)Allow to dry for a minimum of 2 hours or until dry to the touch. NOTE: Cool, humid conditions <br /> may require longer drying times. <br /> a) Because of the absorption characteristics, plywood substrates may require a second pass to fill <br /> any voids at the sheathing joints. After the first pass has dried,check the joints and spot any <br /> voids that may be present with additional Backstop NT-Texture material and allow to dry. <br /> 3) Use a coarse, open-cell foam roller cover with a 3/8 in(9.5 mm)foam nap (FoamPro#58 roller). <br /> Apply a uniform, continuous film of Backstop NT-Texture over the entire surface of the sheathing, <br /> concrete or masonry, including the previously treated areas—Figure 2. NOTE: If the roller pulls <br /> material back out of the sheathing joints, it indicates that the joint material is not sufficiently <br /> dry. <br /> 6 <br />