rl a ,gn <br /> ® °� r kile <br /> Most Widely Accepted and Trusted <br /> ICC-ES Evaluation Report ESR-3319 <br /> Reissued May 2017 <br /> This report is subject to renewal May 2019. <br /> www.icc-eg.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® <br /> DIVISION:07 00 00—THERMAL AND MOISTURE NT can be used in Types I, II, III, IV and V construction. <br /> PROTECTION Under the 2015 IBC for Types I, II, III and IV construction, <br /> Section:07 25 00—Water-Resistive Barriers/Weather use is limited to exterior walls of buildings having a <br /> Barriers maximum height of 40 feet (12.2 m) above grade plane, <br /> Section:07 65 00—Flexible Flashing except for walls in which the water-resistive barrier is the <br /> REPORT HOLDER: only combustible component and the exterior wall has a <br /> wall covering of brick, concrete, stone, term cotta, stucco <br /> DRYVIT SYSTEMS,INC. or steel with minimum thicknesses in accordance with <br /> ONE ENERGY WAY Table 1405.2. Under the 2012 IBC for Types I, II, Ill and IV <br /> WEST WARWICK,RHODE ISLAND 02893 construction, use is limited to exterior walls of buildings <br /> (401)822-4100 having a maximum height of 40 feet(12.2 m)above grade <br /> www.tlrvvit.com plane in accordance with 2012 IBC Section 1403.5. <br /> EVALUATION SUBJECT: The liquid-applied water-resistive barriers,when installed <br /> at a maximum thickness of 20 mils [0.02 inch (0.5 mm)] <br /> DRYVIT BACKSTOP NT WATER-RESISTIVE may be used in fire-resistance-rated exterior wall <br /> BARRIER/AIR BARRIER AND AQUAFLASH FLEXIBLE assemblies recognized in 2015 and 2012 IBC Table 721.1 <br /> FLASHING (2)(2009 IBC Table 720.1 (2)), that specify use of building <br /> 1.0 EVALUA7ION SCOPE paper, without changing the assigned hourly rating of the <br /> Compliance with the following codes: AquaFlash combined with AquaFlash Mesh may be used <br /> ■ 2015,2012 and 2009 International Building Code PBC) as self-adhering flashing under 2015 IBC Section 1405.4 <br /> • 2015, 2012 and 2009 International Residential Code® (2012 and 2009 IBC Section 1405.3) and 2015 IRC <br /> (IRC) Section R7034 (2012 and 2009 IRC Section R703.8), <br /> when installed in accordance with Section 4.3.1 of this <br /> • 2015,2012 and 2009 International Energy Conservation report AquaFlash is limited to use in Type V construction <br /> Cade(IECC) in accordance with the IBC, except under the 2015 IBC <br /> • 2013 Abu Dhabi International Building Code(ADIBC)r where used as flashing for fenestration products as <br /> the 2009 lac.zoos lac code sections referenced allowed under 2015 IBC Section 1403.5, and in structures <br /> 'rne ADIBC is based on <br /> In this roped are the same sections in the ADIac. constructed in accordance with the!RC. <br /> Properties evaluated: 3.0 DESCRIPTION <br /> • Physical properties 3.1 General: <br /> • Water resistance Backstop NT-Smooth and Backstop NT-Texture are <br /> • Surface-burning characteristics factory-mixed, liquid-applied, water-resistive barriers that <br /> are applied over substrates described in Section 3.5.2. The <br /> • Air barrier products are packaged in 5-gallon (19 L)pails and have a <br /> • Types I, II, Ill, IV,and V construction shelf life of two years when stored at temperatures no <br /> 2.0 USES lower than 40°F (4.4°C). The water vapor transmission <br /> value of Backstop NT (when tested in accordance with <br /> Backstop NT-Smooth or Backstop NT-Texture water- ASTM E96, Desiccant Method)is greater than 35 g/m2 per <br /> resistive barriers are used as alternatives to the water- 24 hours, making the products equivalent to a Grade D <br /> resistive barrier specified in IBC Section 1404.2 and IRC barrier. Backstop NT has a flame-spread index of 25 or <br /> Section R703.2 for any type of construction. The barriers less and a smoke-developed index of 450 or less when <br /> comply with ASTM E2570 as indicated in IBC Section tested in accordance with ASTM E54(UL 723). <br /> 1408.4.1.1 and IRC Section R703.9.2.1. The barriers may 3.2 Grid Tape: <br /> be used as an air barrier material in accordance with IRC <br /> Section NI102 and 2015 IECC Sections C402.5 and Dryvit Grid Tape is a self-adhering woven and treated <br /> R402.4 (2012 IECC Sections C4024 and R4024 and glass-fiber mesh that is used with Backstop NT as a <br /> 2009 and 2006 IECC Sections 402.4 and 502.4). Backstop treatment for substrate joints and wrapping of rough <br /> NT-Smooth and Backstop NT-Texture may be used as openings for windows, doors, mechanical equipment, and <br /> water-resistive barriers behind wall coverings. Backstop through-wall penetrations. The fabric is supplied in 4-inch <br /> ICC-ES Y l Repone are nte la 6e eilrolniCd al rep:accrual..<ae.thencs or any other anahnie.not spec f'lly addressed.nor are they lo be con.lmed <br /> a.an endorseinene any fndmRootherbe sublea{If ile M1nm au.rort or a reconanendaaon epeal, andu' ecy as rue red by to n s no warren,.by ICC f I ondxrv2'¢LL erns or mplicd,m' p <br /> anyill <br /> fa pm There, .nw . <br /> CopyngM®2017 ICC Evaluation Service.LLC.All rights reserved panel ot 3 <br />