t2 J z/2S/rat <br /> Air <br /> Alternate Material(s) and/or Method(s) Application <br /> Marion County Public Works <br /> 5155 Silverton Rd NE <br /> auo�tg Salem OR 97305 <br /> OREGON <br /> Phone:(503)588-5147 Fax:(503)588-7948 E-mail:Buildingraico.marion.orus <br /> 104.11 Alternative materials,design and methods of construction and equipment <br /> The provisions of this code are not intended to prevent the installation of any material or to prohibit any <br /> design or method of construction not specifically prescribed by this code, provided that any such alternative <br /> has been approved. An alternative material, design or method of construction shall be approved where the <br /> building official finds that the proposed design is satisfactory and complies with the intent of the provisions <br /> of this code,and that the material,method or work offered is,for the purpose intended,at least the equivalent <br /> of that prescribed in this code in quality,strength,effectiveness,fire resistance,durability and safety. <br /> 104.11.1 Research reports. Supporting data, where necessary to assist in the approval of materials or <br /> assemblies not specifically provided for in this code, shall consist of valid research reports from approved <br /> sources. <br /> 104.11.2 Tests. Whenever there is insufficient evidence of compliance with the provisions of this code, or <br /> evidence that a material or method does not conform to the requirements of this code, or in order to <br /> substantiate claims for alternative materials or methods, the building official shall have the authority to <br /> require tests as evidence of compliance to be made at no expense to the jurisdiction. Test methods shall be as <br /> specified in this code or by other recognized test standards. In the absence of recognized and accepted test <br /> methods, the building official shall approve the testing procedures. Tests shall be performed by an approved <br /> agency. Reports of such tests shall be retained by the building official for the period required for retention of <br /> public records. <br /> PROJECT INFORMATION AND LOCATION <br /> Permit or Activity Number:555-18-008582 —SIR <br /> Site Address:822 Industrial Way,Silverton,Or. <br /> Brief Description of Project: <br /> 25x40 covered patio addition to existing church building which due to the occupant load of the building would require <br /> fire sprinklers.There Is currently no such fire protection in the existing building. <br /> PROPERTY OWNER <br /> Name:Silver Creek Fellowship Phone: ( )503-873-7353 Fax:( ) <br /> Address:822 Industrial Way City/State/ZipSilverton,Or, <br /> APPLICANT—(If Other Than Owner) <br /> Name:Michael Wellman Phone:( )503-873-8111 Fax: ( ) <br /> Address:PO Box 1288 City/State/Zip Silverton 97381 <br /> Relationship to owner:Architect <br /> _DESCRIBE THE REASON FOR THE PROPOSED ALTERNATIVE: <br /> This request is to not have to provide fire sprinklers for the addition as there is currently no means to provide such a system. <br /> The propery is out side the City limits and is not served by an adequate water supply to support fire sprinklers. <br /> The original building was allowed to be constructed without required fire sprinklers by making the construction type II-A, <br /> rated non-combustible.This addition will comply with this construction type. <br /> Page I of2 <br /> tea/ <br />