Laserfiche WebLink
• <br /> Alternate Material(s) and/or Method(s) Application <br /> Marion County Public Works <br /> Marion 5155 Silverton Rd NE <br /> county Salem OR 97305 <br /> OREGON <br /> Phone: (503) 588-5147 Fax:(503)588-7948 E-mail: Buildin carnaaon,or.us <br /> 104.11 Alternative materials,design and methods of construction and equipment. <br /> The provisions of this code are not intended to prevent the installation of any material or to prohibit any <br /> design or method of construction not specifically prescribed by this code, provided that any such alternative <br /> has been approved. An alternative material, design or method of construction shall be approved where the <br /> building official finds that the proposed design is satisfactory and complies with the intent of the provisions <br /> of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent <br /> of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety. <br /> 104.11.1 Research reports. Supporting data, where necessary to assist in the approval of materials or <br /> assemblies not specifically provided for in this code, shall consist of valid research reports from approved <br /> sources, <br /> 104.11.2 Tests. Whenever there is insufficient evidence of compliance with the provisions of this code, or <br /> evidence that a material or method does not conform to the requirements of this code, or in order to <br /> substantiate claims for alternative materials or methods, the building official shall have the authority to <br /> require tests as evidence of compliance to be made at no expense to the jurisdiction. Test methods shall be as <br /> specified in this code or by other recognized test standards. In the absence of recognized and accepted test <br /> methods, the building official shall approve the testing procedures. Tests shall be performed by an approved <br /> agency. Reports of such tests shall be retained by the building official for the period required for retention of <br /> ` Oublic records. <br /> �.. PROJECT INFORMATION AND LOCATION <br /> Permit or Activity Number:i 555-22-006911-15-16-17-18-STR <br /> Site Address: 4044, 4046, 4048, 4050 4052 HAYESVILLE DR NE <br /> Brief Description of Project: <br /> multi family project <br /> PROPERTY OWNER <br /> Name: SPRING WOODS APARTMENTS LLD - Phone: ( ) Fax: ( ) <br /> Address:3842 NW MCINTOSH RD l City/State/Zip CAMAS,WA 98607 <br /> APPLICANT—(If Other Than Owner) <br /> Name:Ronald Pad Phone: ( )5033631456 Fax: ( ) <br /> Address:1504 s Lakeside Drive City/State/Zip 97381 Silverton <br /> Relationship to owner:Architect <br /> DESCRIBE THE REASON FOR THE PROPOSED ALTERNATIVE: <br /> While lire rating between units have the appropriate rating,the STC between units is inquestion because the wrong gypsum wall board in a proprietary assembly. <br /> GA File EC 5414 includes Georgia Pacific 5411 Tough Rock Firegaurd.(product installed).EC 5414 does not include Insulation in the floor,consequently the STC does not <br /> meet the min mum ci 50.The attached calculation on sheet A3.t damenVlltes the calculated STC that exceeds the minimum <br /> Page 1 of2 <br />