Laserfiche WebLink
~2~ch 5, 199~ <br /> <br />DANIEL ~NYDER <br />93-542 <br /> <br />NORTH LOT (~3) <br /> <br /> Your site has been found suitable for a STANDARD ON-SITE SEWAGE DISPOSAL <br />SYSTEM. The following construction specifications shall apply to the installa- <br />tion of your septic system. <br /> <br />1. The septic tank shall have a minimum liquid capacity of 10~ <br /> gallo~s. <br /> <br />The projected dally eewage flow ~0r this project is calculated at <br />450_~allons De~ ,,,day. Based on soil conditions observed on this <br />site, the disposal field will be sized at 150 .lineal fe~t' per ~.~0 <br />~allons of projected daily sewage flow. A min~num O~ 450 13JAeal <br />~get of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed %we (2) feet wide and <br />on minimum ten (10) foot centers and wi~h no line exceediog 125 <br />feet in length. The trenshes and perforated pi~e aP~ installed <br />level (il") and contoured to follow the natural ground surface. <br /> <br />The disposal field ehall be constructed with <br />with a minimum trench depth of 24 i~ohes and a max&mum trench <br />depth of 24 inches. There must be at least .12 inch~ of backfill <br />o~e~ the top of the gravel, measured ~rom the natural ground <br />surface. <br /> <br /> A groundwater interceptor is requi~ed aS part of this system. This <br />interceptor trench must be constructed a minimum twelve (12) inches wide by 40 <br />inches deed with 36 inche~ of clean gravel placed over a four (4) inch ~mooth <br />wall perforated pipe. The interceptor must be lecated at least ten {10) feet <br />upslope from the dlsposal field and must discharge through a watertight, non- <br />perforated pipe beside o= below the disposal field. A separati~n of 25 feet is <br />required from the septic tank if the tank is located upslope of the groundwa~ <br />ter inter~eptor. <br /> <br /> This approval iz site s~ecific to the area tested and the septic ~ystem <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br /> construct the drainfields within the immediate area of the soil test <br /> pits. Avoid the lower northeasterly corner cf the lot. Use ca~e not to <br /> disturb the natural topsoil within the area of the proposed drainfields. <br /> Observe all normal Setback/separation distances. Refer to the enclosed <br /> setbac~ list which outlines minimum separation distances between septic <br /> eystems and other featureS. Keep the house far enough upslope to allow <br /> for a gravity flow into the shallow drainfield lines. <br /> <br />THIS IS NO~ A PEP~4IT TO INSTALL THE SEPT. 0 ~YS%~M. DO NOT I~STA3~L THE SY~T~ <br />~IL A ~tLX,D PERMIT ~L%~ B~N,,I$S~ BY T~S ~FXCE. <br /> <br /> <br />