September 15, 1992 <br />APPLICART~ EL~R cHAS~ <br /> <br /> Your sit~ has been found suitable for a STANDP~D ON-SIT~ ~WAGE DISPOSAL <br />SYSTEH. The following construction s~eci~ications shall apply to the installa- <br />tion of your septic system. <br /> <br /> 1. The septic tank shall have a minimum liquid capacity of 1009 <br /> gallons. <br /> <br /> 2. The projected daily sewage flow for this project is calculated at <br /> ~50 qallon~ ~ dav. Based on soil conditions observed on this <br /> site, the disDosal field will be sized at .~50 linea)~f~et Der 150 <br /> ~allons of projected daily sewage flow. A minimum of ~5.0 lineal <br /> feet of disposal field will be reqlired for your proposed develop- <br /> ment. The disposal ~=enches are constructad two (2) feet wide and <br /> on minimum ten (10} foot centers and with no line ex~ding 12~ <br /> feet in length. The trenches and perforated pipe are installed <br /> level (~l") and contoured to follow the natural ground surface. <br /> <br /> 3. The disposal field shall be ccnst~eted with ~ial distribut~o~ <br /> with a minimum trench depth of 24 inc~e~ and a maximum treneh <br /> depth of ~.Q inches. There must be at least 12 inches of backfill <br /> over the top of the gravel, measured from the natural ground <br /> surface. <br /> <br /> A groundwater interceptor is =eq~ired as pa~ of this system. This <br />interceptor trench must be constructed a minimu~n twelve (12) inohe~ wide by 42 <br />inches deep with 36 inches of clean gravel placed over a four (4) inch smooth <br />wall perforated pipe~ The interceptor must be located at least ten (10) feet <br />upslope frem the d£s~sal field and must discharge through a watertight~ non- <br />p~rforated pipe beside or b~lew the disposal field. A separation Of 25 feet is <br />reqUired from the septic tank if the tank is louated upslo~ of the groundwa- <br />ter intercepter. <br /> <br /> An effluent lift pump may be necessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval is site specific to :he area tested and the septic system <br />mupt be located in the immediate area of the test pits unless otherwise <br />rized by this office. A new site evaluation may be reqUired if the syst~ is <br />proposed for a diffeFent area on the property. <br /> <br />SPECIAL ~ONDITION$: <br /> The existing lower soil test pit is dug too close to ~he downslope road <br /> cut and ditch. Also, too close to the proposed well. The draiufields <br /> will need to be shifted fa=ther upslope and the well will need ~0 be <br /> relocated or eliminated altc~ethe~ and the residence serviced from an <br /> offsite water ~pply. Refer to the enclose~ setback list which outlines <br /> minimum separation distances between eomponents of the septic systems <br /> a~d othe~ features~ existing and proposed. The new lot lines must me~t a <br /> ten (10} feet mini~az~ setback from the existin~ adjacent drainfi~ld and <br /> the replacement drainfield sites. A prec0nStruCtion field stakeout is <br /> recommended. Refer to the enclosed stakeout procedure to complete the <br /> stakeout. <br /> <br />~ZL A V~LID PERmiT ~ ~ ISSI~,,BY T~I~ <br /> <br /> <br />