Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br />?TE/TI~E 65/21/75 <br />ERflIT NO ~ ?§-1~91~ <br />tYPE <br />;LABS <br />]CCUPA~CY : <br /> <br /> 285Chu~h~i~etNE ' Room 132 ,salem, Ol~gon~7301-3670 <br />Office Hours:8:00~=30 · Phone:(5~)~147,~HRIns~Li~:(~)588-79~ <br /> SEPTIC P~H[T <br /> ~P~IED ~ B~/~B/~995 <br /> Tg ~PXRE : ~3/2~/1996 <br /> <br /> SEPTIC <br /> <br />Fhis 'ro,e~t was previcusl evalated 10/21./1793 fc~' the feasibility .tD.~st~l]; a ~ <br /> <br />~ ~h~, o-F'fic~. ~ new site evaluation ~ay be required l~ ~he sy~ ~$ propos.u ~o, a <br />~f~eren'~t area od the <br />th-'= ~n''va] wa~ ive~ o~ k'e [aS~ U~at ~he 1o~ or parcel w~[1 no~' b$ further partitioned <br /> ~ubdiv~ded and ~hat coYdit~o~s o~ ~his proper ' <br />?~ ~*~v ~ ~'~ ;h~ch W~Ltld oT'Ohibi~ the ~$5ua~8'0~ a pe?~. SO~S ~n ~he ap~?yed <br />,, . / . " .... ' . ' · - ' lo ~e~tal act~visies which ~o ic <br />shall ~of be altered by cutt~g~ fzllings.p~ pther deye p ..... , . ~;;?, <br /> <br />to co:,~ply with t'l~e above tter.~s May void this <br />the site evalua'tion approval runs ~th ~he land~ bu~ the permit is ~o~-transfel*abie at~d norr~ <br />refundable. <br /><eep t'hi~ docu~,~en~ with your records. Show ~his per~i~ tO the septic instalIe~ prior to <br />installation of the system. Any deviation f~oM.the app~oved plan ~USt have pr[o~ approval <br /> <br />The following cons~ructton 5peciflcat~on5 shall.apply to the Installation of ~he initial <br />sept'it sys'te~: <br /> <br /> TYPE OF INITIAL SYSTEM: ~TAN~AR~. <br /> MtHIHUM SEPTIC TANK CAPACITY:18BB ~ALLONS <br /> _INLAL FEET OF ~RAINF[EL~. <br /> TYPE O~ D~STRIBUTION~ SERIAL <br /> ~ISPOeAL TRENCH QEPTH: 24 INOHES~ MIN; 24 INCHES, MAX <br /> TOTAL. QRAIN ME~IA ~EPTH: 12 <br /> DRAIN HED~A UNQER PIPE: <br /> MINIMUM SOIL BACKFILL: 1~ INCHES <br /> GROUND WATER INTERCEFTOR~ Y <br /> The di~posal trenche~ are constr~cted two (2) fee~ w~8 8~d o~ miniMue~ ten (I~) foot' centers <br /> and w'it~ no line exceeding 12~ fe~t in. leng~h~ The trenches and perforated pipe are <br /> install, ed level (+/- one ~.nch) ama contoured so follow the natural grouod surface. <br /> <br />TYPE OF FUTURE REPLACEMENT SYSTEM: STANDARD <br /> <br />~OMHENTS AND CONDITIONS <br /> <br />I. THIS SIL"PTIC REVIEW WAS COMPLETED By' ROBERT FOSTER on <br /> MARCH t.~,~ 197u. · <br />'2. 'The attached (]RANGE CARD ~ust ~e posted et the countx roma. <br />3. The site r~ust be protected f~o~ trafftc~ livestock, farMinQ <br /> o- or'e- d~aQin~ activities. ' .. , <br />4,, Thief sy~ ~u~t' be inspected p~ior to cover. To reques~ <br />a~ znspmction of completed work~ call ~B8-7?~4 (24-hOU~ <br />~,iR'~ ~ ? re~;ues~io the inspection be sure to iv <br /> length of dsainfield. I~spec%[on ,iii be completed within <br /> seven days o~ request. <br />:='i~ A gr~ondwater &otercepto~ ts requite~ m~ part of this <br /> syi[tm~u This interceptor ~rench mus~ be constructed a <br /> ~,d,u:h,~u~ ,?welve (12) in~hes wide by forty-eight (48) ~ncbes <br /> ~,,,~,p ~t"~ t"~irt'y-six (~) i~shes of c~ean ~Favel placed over <br /> <br /> <br />