FOUNDATIONS <br /> <br /> 1. Footings shall bear on firm <br /> undisturbed soil. <br /> <br /> 2. Fills to be used to support <br /> footings shall be engineered (report <br /> required) or shall be concrete. <br /> OUBC 2903-a <br /> <br /> 3. Foundation sections 12"/15"/18" <br /> <br /> depth below natural grade and finish <br /> grade are required. OUBC Table 29-a <br /> <br /> 4. Provide underfloor vents of 1 <br /> sq. ft. per 150 sq. ft. of <br /> underfloor area. Openings shall be <br /> as close to corners as practical and <br /> provide cross ventilation. OUBC <br /> 2516 (c)-6 <br />~ Provide.underfloor drainage if <br /> ~pace is sub]ect to potential storm <br /> or groundwater accumulation. <br /> OUBC 2910 <br /> <br /> 6. Reinforcement required for <br /> foundation walls. <br /> <br />7. Extended 1/2" sill bolts, min. <br />7" into concrete. Space max. 6' <br />c.c. and within 12" of ends. 2907 <br /> (f) <br /> <br />8. Provide min. 18" x 24" access <br />to crawl space, located not over 20~ <br />from plumbing cleanouts (OUPC 406-g) <br />or furnace (0UMC 804-b). Pipes, <br />ducts and other nonstructural <br />construction shall not interfere <br />with accessability to or within the <br />crawl space. OUBC 2516 (c) 2. <br /> <br />9. Vapor barriers shall be <br />installed on the ground in crawl <br />spaces and on the warm side of <br />exterior walls. 5303 (f) 5. Ground <br />cover shall turn 12" up the <br />foundation wall. <br /> <br />10. The required clearance for wood <br />members above grade is 6" for <br />mudsills, 12" for girders and 18" <br />for joists. OUBC 2516 (c) <br /> <br />11. Ail posts to be mounted on <br />approved supports. OUBC 2516 (c) 4 <br /> <br />CONSTRUCTION REQUIRFd4ENTS <br /> <br />~. Fire block studwalls and <br />partitions (including furred spaces) <br />at floor, ceiling, soffit and at mid <br />height and along stair stringers. <br />Draft stops shall be provided in the <br />following locations. (1) in the <br />concealed space of a floor ceiling <br />assembly in a single family dwelling <br /> <br /> di~idin~ the area in to equal spaces not <br /> ove-r 10~0 sq. ft. <br /> (2) Draft stops shall be installed in the <br /> attics, mansards, overhangs and similar <br /> concealed spaces of buildings containing <br /> more than one dwelling unit. Such draft <br /> stops shall be above and in line with <br /> walls separating tenant spaces from each <br /> other. OUBC 2516 (f) <br /> <br /> 13. Garage door header shall be min. <br /> ~.F. #2 with double cripples. <br /> <br /> 14. Use header, beam or rafter sizes <br /> noted on the plans. <br /> <br /> 15. Trusses shall be engineer approved. <br /> Provide trusses details to Marion County <br /> Building Department before framing <br /> inspection. <br /> <br /> A ridge board not less in depth than <br /> 1~ cut end of the rafter is required. <br /> It shall be a vertical load bearing <br /> member when roof slope is less than 3" in <br /> 12". OUBC 2517 (h) 3 <br /> ~. Rafter ties spaced max. 4' c.c. are <br /> ~a~equired ~mmediately above ceiling joists <br /> which are not parallel to the rafters. <br /> OUBC 2517 (h) 4 <br /> <br /> .~8~. Roof purlins must not be smaller <br /> ~cSa <br /> n the rafters they support. The max. <br /> Span for 2 x 4 / 2 x 6 roof purlins is 4' <br /> & 6' For purlin supports provide <br /> struts, not smaller than 2 x 4 with an <br /> unbraced length not over 8 ' and not <br /> flatter than 45 degrees to the gorizontal <br /> to bearing wall or partitions. OUBC 2517 <br /> (h) 5 <br /> <br /> ~. Ail weather exposed plywood shall be <br /> EXTERIOR type and at least C-C grade. <br /> Attention: Roof overhangs. <br /> <br /> Provide screened attic vents with a <br /> free area of 1/150 of the attic area <br /> (or 1/300 if half is along eaves and the <br /> balance at least 3' higher). OUBC 3205-c <br /> <br /> 21. Roof shall be sloped for drainage. <br /> Valleys shall be supported (flat valleys <br /> prohibited.) Shingles (any kind) shall <br /> not be installed on a slope of less then <br /> 4" in 12". composition shingles require <br /> a 15 pound asphalt felt base sheet. <br /> Chapter 32. <br /> <br />2~ep Provide min. one hour fire <br /> aration between garage and house. <br /> Separation shall extend to roof line or <br /> across ceiling and remaining bearing <br /> walls. Use min. 1 3/8" solid core door. <br /> OUBC 503 (d) exception 3. <br /> <br />g Elements of appliances which create <br /> low, spark or flame shall be located a <br /> min. of 18" above garage floor. OUMC 508 <br /> <br /> ~./ Appliances subject to mechanical <br /> d~a4%age shall be guarded by a protective <br /> barrier. OUBC 508 <br /> <br /> tClothes dryer located in an area <br /> is habitable or containing other <br /> fuel burning appliances shall be <br /> exhausted to the outside. OUMC 1903 <br /> <br /> <br />