MANF - 1447854
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
96-XXXXX
>
MANF - 1447854
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2010 10:53:23 AM
Creation date
7/6/2004 10:07:15 AM
Metadata
Fields
Template:
Permits
Permit Address
729 STAFFORD ST
Permit City
AUMSVILLE
Permit Number
555-96-04023
Parcel Number
081W30 02300
Permit Type
MANF
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours: $:00-4:30 * Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br />~ATE/TIHE <br /> YPE <br />OCCUPANCY <br /> <br /> HAHUFACTURED DI~ELLIHI; PERI'IT <br /> : S6/12/9& B6.'31 PERHIT NS -' 96-G4~23 <br /> = Ne~ Hanufactured D~el/ing STATUS = ISSUED <br /> = R-3 ISSUED = ~6/12/1996 <br /> TO EXPIRE = 12/e9/1996 <br /> PAGE 3 <br /> Mem~fac'~ured dwelling ready for occupancy. Assigned street nuMbers shall be <br /> painted or affixed to the front of the dwelling in a contrasting a;~d <br /> v~sib]e color, not less th,~n four (4) inche~ In height. <br /> <br /> Thi~ ins;pettish include~ checking construct:i, on and code requirements for d~'~cks <br /> and steps, skirting and underf[oor ventilation and access. <br /> <br />A REINSPECTION FEE OF $&B. SB shall b~ assessed for each ~nspection beyond the <br />permitted thre~ inspections or (1) when thP permit card is not pos'OeO <br />on t~e job ~ite] (2) for failure to provide access on the date for which <br />the ~n~pec~:~on ~.s requested; (3) when the work for which an inspection is <br />requested ~.s not coM~l, ete, (4) when the ~anufactured dwelling is not installed <br />per.~& ~¥~uf~ctur~ ~w~]ling Standard~, (5) for failing to attach an install(.~r's <br />c~:s?casz~n ~a~ or.(6) when required r:orrections are not Made. No inspectio~s <br />~.[~ o~ per'forMes unfit the reinsoection rep has bee~ paid at our office. <br /> <br /> 1. THIS PLAN REVIEW WAS COMPLETED ~Y S. FREILIflGER ON 6/7/96. <br /> 2. Approval.o~_su~M~d pla~s is no[ an approval of omissions <br /> or overs[gn~s oX ~rt~.s off,ce or o~ nonCOMpliance with any <br /> applicable regulations of local 9overnM~n[. <br /> ~. A roadside Marker shall be place~ at the access point with <br /> address numbers in a contrasting and hJgi~ly visible color, <br /> not less tha~ three (3) inches ~n heiqht. <br /> 4. Site grading a~d drainage shall proviSe grades which slope <br /> downward a~ay fFOM Manufactured dwellin~ stands, foundation <br /> footings, concrete slabs, patios, walls, skirting~ and <br /> foundations at e MINIMUM GRADE OF 1/2 IHCH PER FOOT FOR 5 <br /> ~EE~.hor~oqtm].~y. ,(S~c~ion 382(c) 1994 Oregon Manufactured <br /> welling [,one <br /> 5. Provide at least 1 squnre foot of onderfloor ventilation <br /> for e~ch 158 square feet of crawl ~pace area. The openinqs <br /> ~ha]l be covered with a corrosio~ re~istar~t wir~ Mes~. A~ <br /> least one such opening shall be provided ~ithin 3 feet of <br /> each corner of the building. (R-J11.1) <br /> ~.Provide an.mccess crawl hole to the underfloor space. The <br /> MiniMuM si~.e opening required is 18 inches by 24 inches. <br /> <br /> 7. St~:irwmys shal~ ~ot be les~ than 3 feet in clear width a~d <br /> ~he headroom shall not Oe less tha~ 6 feet 8 inches. The <br /> MiniMUM required stair tread width is ? inches. The <br /> MaxiMuM stair rise is 8 inches. When risers are <br /> closed, all treads May have a u~iforM projectim'~ not to <br /> ~xceed 1 and 1/2 inches. The greatest riser heiqht shall <br /> not ex~'eed the smallest b~ Mo~'e than J/8 i~ch. 1R-21J.1) <br /> p~v~ d,~d on mt l~as'[ nyse side G'~ st'airwoys.~ ' ~'he' ~and0rip <br /> p~,r;-~ )~.~ of handrails shall )~ ~ot e~o~-~, than 2 5/8 inches <br /> (~'~.~.~-s~.ctionel dimension, o~ the sl~ape shall provide ~n <br /> ?~'[velent gr~pping~sg[f~e~ Handrails shall be Mounted <br /> They ~hall be co~'r~.[~uous~ ~h~ full length of the stairs; <br /> Fod~ sh<~] b~ retur¥~ed o~' shall terMina'te in newel pos'5 o) <br /> sa fet~ terminals. <br /> (R-21~. 1) <br /> ~. A MiniMUM ~' x ~' landing sh~ll he required on each side of <br /> mn egre~s door'. The floor or landing shall ~ot be More <br /> than one m~d one-half inches lo,er than the top of the <br /> threshold. (R-212) Exception: The landing on the <br /> exterior side of an exterior doorway shall not be More than <br /> 8 mod 1/4 inches below the top of the threshold. <br /> 18. Porche% balconies or raised floor surfaces located More <br /> then J8 i~. above the floor or grade shall have guardrai] <br /> not [ess than ,t6 ~nches in height. Required guardrail sh~ll <br /> hl, ve intermediate rails or or~3mental closnres which <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.