Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 · Phons: (503) 588-5147 * 24-HR Inspection Line: (503) 373-4427 <br /> <br />DATE/TIHE <br />TYPE <br />OCCUPANCY <br /> <br /> #ANUFACTURED DI~LLIHG PERHIT <br /> = ~3/19/77 14=44 PERHIT HO = 77-~1565 <br /> = New Hanufactured D~elltng STATUS = ISSUED <br /> = R-3 ISSUED = ~3/19/1797 <br /> TO EXPIRE = 09/15/1997 <br /> PAGE 3 <br />~anufacture¢ dwelling ready for occupancy. Assigned street numbers shall be <br />painted or.affixed to the froot of the dwelling in a contrasting and highly <br />visible COlOr, not less than four (4) inches in height. <br />This inspection includes checking construction and code requirements for decks <br />and steps, skirting and uoderfloor ventilatiot~ and access. <br /> <br />A REINSPECTION FEE OF $60.08 shall be assessed for each inspection Oeyond the <br />permitted three inspections or (1) when the permit car~ is not posted <br />on the ~ob site; (2) for failure to provide access on the date for which <br />the inspection ~s requested; (3) when the work for which an inspection is <br />~'equested is not complete, (4) when the ~anufactured dwelling is not installeO , <br />per I?76 Manufactured Dwelling Standards, (5) for failing to attach an installer s <br />certification taq, or (6) when required corrections are not made. No inspections <br />will be perforMe8 until the reiospectio~ fee has been paid at out* office. <br /> <br /> OTHLK CUHMkNT$ AH~ CONDIIiUHS <br /> <br /> i. THIS PLAN REVIEW WAS COMPLETED BY S. FREILINGER ON 3/18/77. <br /> ?. Approval Df submitted plans is ~ot an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 3. A roadside Marker shall be placeB at the access point with <br /> address numbers in a contrasting and highly visible color, <br /> not less than three (3) inches in heiqh~. <br /> 4. Site grading and drainage shall proviSe grades which slope <br /> downward away from manufactured dwelling stands, foundation <br /> footin§s~ concrete slabs, patios~ walls, skirting, and <br /> foundations at a MINIMUM GRADE OF 1/2 INCH PER FOOT FOR <br /> FEET horizontally. (Section ~02(c) 1976 Oregon Manufactured <br /> Dwelling Code Standards). <br /> 5. Provide at least 1 square foet of underfloor ventilation <br /> for Wach 158 square feet of crawl space area. The openings <br /> shall be covered with a corrosion resistant ~ire Mesh. <br /> lea~t one suc~ ~peo~mg ~hall be provided within J feet of <br /> eacn corner o~ =ne =uil~ing. (R-~11.1) <br /> 6. Provide an access crawl hole to the underfloor space. The <br /> M~niMuM size opening required is 18 inches by 24 inches. <br /> (R-~11.2) <br /> 7. Stairways shall not he less than J feet in clear width and <br /> the headroom shall out be tess than 6 feet 8 inches. The <br /> minimum required stair tread width is 9 inches. The <br /> Maximum stair rise is 8 inches. Wheo risers are <br /> closed, all treads May have a uniform projecti=n not to <br /> exceed 1 and 1/2 inches. The greatest riser h'eiqht shall <br /> not exceed the smallest by More than 3/8 inch. 1R-213.1) <br /> 8. Handrails meeting the following requirements shall be <br /> provided on at least one side of s~airways. The handgrip <br /> portion of handrails shall be not More than 2 5/8 inches in <br /> cross-sectional dimension, or the shape shall p~ovide an <br /> equivalent gripping surface. Handrails shall be Mounted <br /> between a minimum of ~8 inches and a Maximum of ~8 inches. <br /> ~h~y shall be continuous the full length of the stairs. <br /> nos shall be returned or shall terminate in newel posts or <br /> safety terminals. <br /> (R-214.1) <br /> 9. A minimum 3' x ~' landing shall be required on each side of <br /> an egress door. The floor or landing shall not be MOre <br /> than one and one-half inches lower than the top of the <br /> threshold. (~-212) Exception: The landing on the <br /> ~xterior side of an exterior doorway shall not be more than <br /> u and 1/4 snches ~elow the tO~ of the threshold. <br /> !B. Porches~ balconie= or raised float surfaces located P~ore <br /> than 30 irt. above the fi. our or ~¥ade shall have guardrail <br /> not ].ess than 36 inches i~ height. Required guardrail shall <br /> have intermediate rails or ornamental closures which will <br /> <br /> <br />