Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lancaster Dr. N.E. · Suite C · Salem, Oregon 97305-1398 <br />Office Hours: 8:00-4:30 * Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br />NATE/TINE : <br />TYPE : SE <br />OCCUPANCY : R-3 <br /> <br />SITE EVALUATION APPROVAL <br /> <br />16:47 <br /> <br />APPROVAL HO : 97-B2457 <br />STATUS : APPROVED <br />APPROVED : ~5/12/1997 <br /> <br />PAGE 2 <br /> <br /> SITE EVALUATION APPROVAL <br />'Ibis property has be~n evaluated for' the feasibility of the installation of' a septic <br />system for a RESIDENTIAL buildino site. Based on the results of this study~ site evaluation <br />approval :is granted. The approva~ is site specific to the area tested, and ~he septic syste~ <br />Must he located in tte immediate area of the test pits~ unless otherwise authorized by this <br />office. A ~ew site evaluation May ~e required'if the'syste~ is proposed for a different <br />area on the property. <br /> <br />Th~s approval is g:iver~ on th~, ba?d~ that the lot or parcel will rmt be further partitioned <br />or subdivided and that conditirms on this property and on adjacent properties are not altered in <br />any Manner wbi~h would prohibit the issuance of a per,it. Soils in the approved area shall not be <br />altered or Modified by cutting, filling~ or other develop~ental activities which would impede the <br />successfu) operation of the inxtial or replaceMe~t soil absorption systems. Failure to comply wit~ <br />the above items ~ay void this approval. <br /> <br />'ibis report is not a p~rM:lt to in~ta]] the sewage system. A permit ptust be obtai~ed before <br />~any system construction occu-~. A permit May be issued only afte- the property has been found to <br />h~ co,~pat~ble with applicable LC~C acknowledged local comprehensive land use pla~. A Statement of <br />Land Use Compatibility or its equivalent is required before a construction permit can be issued. <br /> <br />A detailed site plar~ drawT~ to scale (ex: 1" = 68")~ Must be submitted with the permit <br />application before the construction-installation permit can be issued. The system M~lst be <br />~'mt~lled by tl~e property owner or a registered cor~tractor. <br /> <br />This sit~.evaluat&Dn report is valid until an on-site sewage syste~,~ is installed pursuant to the <br />~on~truc~on perM~ obtained from th~s off~ce, or until cancelation pursuant to the Environmental <br />Quality CoM~li~sio~ Rules~ Subject to the above, this report runs with the land and will automat- <br /> <br />Site cm~ditions will require the following installation specifications: <br /> <br />TYPE OF INITIAL SYSTEM: <br /> <br />STANDARD <br /> <br />HINIMUM S..FIlC 'TANK CAPACITY: 1080 GALLONS <br />LINEAL FEET OF DRAINFIELD: 150 <br />TYPE OF DISTRIBUTION: SERIAL <br />~SPOSAL TRENCH DEPTH: 24INCHES~ MINIMUM; ~6INCNES, <br />TOTAL. DRAIN MEDIA DEPTH: 12 <br />DRAIN MEDIA UNDER PIPE: 6 <br />M.[NIMUM SOIL BACKFILL: 12 <br />GROUND WATER INTERCEF'TOR: N <br /> <br />MAXIMUM <br /> <br /> TYPE OF FUTURE REPLACEMENT SYSTEM: STANDARD <br />t~efore any i~stallat~nn tal(es place, a per'mit Must first be obtained from Mar'ion County. <br /> <br />CONMENTS AND CONDITIONS <br /> <br />1~ TBIS SEPTIC REVTFW WAS COMPLETED BY LEE GRIMES ON APRIL 14 <br /> ]~77. INSTA[.L'"Tfl~ DRAINFIELD LII,IE~ WITHIN THE IMMEDIATE AR~A <br /> OF THE SOIL TEST F_TS. REFER TO THE ~ITE PLAN DATED MAY 12~ <br /> ~7. URF CARE' NOT TO ALTER THE NATURAl. TOPSOIL WITHIN THE <br /> I)kA.NFIELD SITES PRIOR TO INSTALLATION. SUMMER SEASON CON- <br /> STRI(.IION IS RECOMMENDED TO PREVENT SOIl. COMPACTION DURIN~ <br /> IS[~A.[.~LATION..OBSERVE ALL ,USUAL SETBA~ ~ AND SEFARATION DIS- <br /> IAN(.F.S. THIS EYAL.AIlON IS TO CONSIDER A TWO BEDROOM MAXIMUM <br /> RESIi)ENCE. <br /> <br /> <br />