Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 · Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br />DATE/TIME : 64/11/97 <br />TYPE : SE <br />OCCUPANCY : <br /> <br />16:17 <br /> <br />SITE EVALUATION APPROV~tL <br /> <br />APPROVAL NO : 97-62236 <br />STATUS : APPROVED <br />APPROVED : 64/11/1997 <br /> <br />PAGE 2 <br /> <br /> SITE EVALUATION APPROVAL. <br /> <br />This property has been evaluated for the feasibility of the installatio~ o'F a septic <br />system for a RESIBENTIAL building site. Based on ~he results of this study, site ew~luation <br />~pprowl is ~r~nted. The ~prow~l is site specific to the area tested~ and the septic syste, <br />~,~ust be lo~a~ed ir~ the i~Mediate area of the test pits, unless otherwism authorized by this <br />o~f~:~. A n~w sit~ evaluation may be required if the system is proposed for a different <br />area on the property. <br /> <br /> Fhis approval is given on the basis that the lot or parcel will not be further partitioned <br />or subdivided m~*td ~hmt conditions on this property and on adjacent properties are not altered in <br />any ~nner which would prohibit the issuanc~ of a permit. Soils in the approved area shall not be <br />altered or modified by cutting~ fill:ing~ or other developmental activities which would impede the <br />sucr. e~ssful operation of the initial or replacement soil absorption systems. Fail re tc :o~ply with <br />the above iteMs may void this approval. <br /> <br /> Ih[s ~:~oz,. tS ~ot ~.p~rm~t [.o [~stall the sewage systeM. A permit ~ust be obtained before <br />any systems ~ons~ruc~[on occurs. A permit May be ~ssued only after the prope'*ty has been found to <br />b~.~ coi'~pmt~ble with applicable LC~C ~cknowledged local comprehensive lan~ use plan. A Statement of <br />L~nd U~e Compatibility or its equ:i:va].e~t i~ required before a construction permit can he issued. <br /> <br />A d~t.a[led site plan, h~w ~o scale (ex. 1 - ~8 ) ~ust be ,ubM[[ted with the permit <br />~,ppl~cat[on before the cm*mtru(~tlon-l~stallat[on perMit can be issued. The system Must be <br />installed by the property owner or a registered co~tractor. <br /> <br />*Ibis site evaluation report is valid until an on-site sewage system is installed pursuaYtt to the <br />construction per,it obtmin~ from this office~ or [nbil cancelation pursuant to the Envi*o~enfat <br />~ ality Co, Mission Rules. Subject to the above~ t~is report runs with the la~d and will automat- <br />ically benefit subsequent owner~ <br /> <br />~te cond:~tions will require tl~e following installation specifications: <br /> <br />TYPE OF INITIAL SYSTEM. <br /> <br />STANDARD <br /> <br />MINIMUM SEPTIC TANK CAPACITY: 1000 GALLONS <br />LINEAL. FEET OF QRAINFIELD: ~75 <br />TYPE OF BISTRIBUTION: SERIAL <br />DISPOSAL TRENCH DEPTH: 24INCHES~ MINIMUM; ~6INCHES~ <br />TOTAL DRAIN MEDIA DEPTH: 12 <br />DRAIN MEDIA UNDER PIPE: 6 <br />MINIMUM SOIL BACKFILL: 12 <br />GROUND WATER INTERCEPTOR: N <br /> <br />MAXIMUM <br /> <br /> TYPE OF FUTURE REPLACEMENT SYSTEM: SAND FILl'ER <br /> <br />Before a~y installation takes pil. ace~ a permit Must first be obtained from Marion County. <br /> <br />COMMENTS AND CONDITIONS <br /> <br />THIS SEPTIC REVIEW WAS COMPLETED BY LEE GRIMES ON APRIL 3~ <br />t?~7. SITE CONDITIONS ARE MARGINAL BUE TO THE LIMITEB AREA <br />01~ SUITABLE TO CONSIDER STANDARD SYSTEM BRAINFIEL~S. DRAIN- <br />[.lINES MUST BE LOCATED WITHIN THE IMMEDIATE AREA OF THE UPPER <br />TWO 'rEST P1TS. A PRE-F'ERMIT FIELD STAI(EOUT IS NECESSARY TO <br />~ONFtRM THE LOCATIONS OF' ~HE INOlVTQUAI DRAINLINES ANB TO <br /> STABLISH WHET~ER'AN ALTERNAT~VE'S~ND ~'ILTER SYSTEM WILL. BE <br />~6~0~ ~ ~ REPLACEMENT SY~,TEM. REFER TO 1HE STAKEUOT <br /> SETBACK LIST FOR DETAILS TO COMPLETE THE <br /> <br /> <br />