Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lancaster Dr. N.E. · Suite C · Salem, Oregon 97305-1398 <br />Office Hours: 8:00-4:30 * Phone: (503) 588-5147 * 24-HR Inspection Line: (503) 373-4427 <br /> <br />DATE/TINE <br />TYPE <br />CLASS <br />OCCUPANCY <br />CONSTRUCTION <br /> <br /> BUILDING PERMIT <br /> : 86/13/97 89:59 PERMIT NO <br /> : Resident. addition/alteration STATUS <br /> : D~elling addition/alteration ISSUED <br /> : R-3 TO EXPIRE <br /> : V-N PAGE <br /> means shall be provided to ensure positive drainage. <br /> [Sec. 401~i~] <br />11. FINISHED GRADE. Footings sha]l extend not less than 12 <br /> inches below the finish natural grade. Foundation walls <br /> shall extend at least 6 inches above the finished grade <br /> adjacent to the foundation at all points, except 4 inches is <br /> allowed where Masonry veneer is used. [Fig. 403.1a, <br /> SectioM 404.1.3] <br />12. ANCHOR BOLTS. Foundation plates shall be bolted to tile <br /> foundation with a minimum 1/2 inch diameter by 10 inch <br /> anchor bolts embedded at least 7 inches into concrete or' <br /> reinforced masonry~and spaced not more tha~ 6 feet apart <br /> with a Minimum of ~ bolts per piece with one bolt within <br /> 12 inches of the end of each piece. IFil. 40~.1a3 <br />~ BP. This structure uses Brace Wall Panels (BP) to Meet the <br /> code requirement for lateral wall bracing. Insure that all <br /> BP's are located as indicated on the plans. <br />14. LANDING / EXTERIOR DOOR. A minimum 3 foot x ~ foot landing <br /> shall be required on each side of an egress door. The floor <br /> or landi~g shall not be MOre than 1 an~ I/2 inches lower <br /> than the top of the threshold. Exception: The landino at <br /> the exterior doorway shall not be More than 8 1/4 inch~s <br /> below the top of the threshold. [Sec. ~12. t] <br />;5. SMOKE OETECTORS / ALTERATIONS. When alterations, repairs or <br /> mdditions are Made to an existing dwelling, the eMtire <br /> building shall be provided with smoke detectors located as <br /> ?equireO for new dwellings. The smoke detectors are not <br /> required to be interconnected unless other remodeling Con- <br /> siderations require red, oval of the approp'iate wall and <br /> ceiling coveri~igs to facilitate interconnecting wiring. <br /> [Section <br />1~6. SMOKE DETECTORS shall be installed iM each sleeping room, <br /> outside of each separate sleeping area in the iMMeOiate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements. All detectors shall be inter- <br /> ,~oonect~d such that the actuation of one alarm will actuate <br /> all the alarms in the individual unit and shall provide an <br /> alarm which will be audible in all sleepin~ areas. <br /> [Sectim~ ~1~.13 SMoke detectors shall be ~18 volt with <br /> battery back-up. [Sec. 316.2] <br />~7. ENERGY PAIH ~1 is based on R-21 wall insulation, R-25 under- <br /> floor insulation, R-30 Vaulted ceiling insulation, ~--38 flat <br /> c~iliog insulmtion, R-21 baseMenet wails, R-15 slab floor <br /> edge insulation~ R-8 forced air duct insulatioo~ <br /> 0.40 U-value window class, 0.58 U-value skylight class, <br /> 8.54 U-value Maim entry door, (with a MaXimum area of ~4 <br /> square feet) ali other exter~.or doors, including the door <br /> between the beated dwelling and the unbeated garage, 8.20 <br /> U-value. <br /> <br />77-~389B <br />ISSUED <br />B6/13/1997 <br />12/18/1997 <br /> <br /> <br />