Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lancaster Dr. N.E. · Suite C ° Salem, Oregon 97305-1398 <br /> Office Hours: 8:00-4:30 ° Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br /> SITE EVALUATION APPROVAL <br />~7/21/97 ~lt4? ~°PEOVAL HO ~ 97-~3947 <br /> <br /> : 17/21/1~7 <br /> <br />PAGE 2 <br /> <br /> SITE EVALUATION APPROVAL <br /> <br />Th~s prnperty has been evaluated for the feasibility of the installation of a septic <br />systen for a RESIDENTIAL building site. Based on the results of this study, site evaluation <br />approval is granted. The approval is site specific to the area tested~ and the septic systen <br />oust be located in the immediate area of the test pits~ unless otherwise authorized by this <br />office. A new site evaluation may be required if the syste~ is proposed for a different <br />area on the property. <br /> <br />Th~s approval is given on the basis that the lot or parcel ~ill not be further partitioned <br />~r subdivided and ~hat conditions on this property and on adjacent properties are not altered in <br />any manner which ~ould prohibit the issuance of a permit. Soils in the approved area shall not b~ <br />altered or ~odified by cutting~ filling~ or other developmental activities which would impede the <br />successful operation of the initial or replacement soil absorption systems. Failure to comply ~ith <br />the shove items nay void this approval, <br /> <br />Th~s report is not a permit to install the sewage system. A permit must be obtained before <br />pny syst?m.~onstructioD occurs. A permit may be issued Only after the property has been found <br />De compa~inie with applicable LCDC acknowledged local comprehensive land use plan, A Statenent <br />Land Use Compatibility or its equivalent is required before a construction permit ca~ be issued. <br /> <br />A detailed site plant dra~n to scale (ex: l" = &O")~ must be submitted with the permit. <br />application hefore the construction-installation peE~it can be issued. The system ~ust be <br />installed by the property o~ner or a registered con~ractor. <br /> <br />This site evaluation report is valid u~til an on-site sewage system is installed pursuant to the <br />construction per~i~ obtained from this officer or until cancelation pursuant to the Environmental <br />Quality. Co~issio? Rules~ Subject to the abeve~ this report runs with the land and will automat- <br />icallX DeneTit suDsequen~ o~ners. <br /> <br />Site conditions will require the follq~ing installation specifications: <br /> <br /> TYPE OF INITIAL SYSTEM: <br /> <br />MINIMUM SEPTIC TANK CAPACITY: ~ GALLONS LINEAL FEET OF DRAINFIELD: <br /> DT~S~[ DISTRIBUTION: SERIAL <br /> TRENCH DEPTH: 241NCHES, MINIMUM~ 24IHCHES~ MAXIMUM <br /> <br /> I I 0 FI : <br /> <br />STANDARD <br /> <br /> TYPE OF FUTIJRE REPLACEMENT SYSTEM: SAND FILTER <br /> <br />Before any installation takes place~ a permit must first be obtained from Marion County. <br /> <br />COMMENTS AND CONDITIONS <br /> <br />THIS SEPTIC REVIEW WAS COMPLETED BY LEE GRIMES ON JULY 15 <br />1997. SOIL CONDITIONS AT THE TEST PITS ARE MARGINAL TO <br />CURTA NSIDERIA STANDARD SYSTEM DRAINFIELD PROTECTED WITH AH UPSLOPE <br /> BRIAN FOR THE INITIAL SYSTEM. AN ALTERNATIVE SAND <br />FILTER SYSTEM IS NECESSARY FOR FUTURE REPAIRS. AN EFFLUENT <br />PUMP MIGHT BE NECESSARY TO INSTALL THE DRAINLINES AS STAKED <br />FR <br />l~, ~.TI~t ~RN~ ~T~t.~.RANTH~NATURALTHE ST~EEOUTToPSOiL~TEDw[THiNJULY <br />THE DRAINFIELD SITES PRIOR TO INSTALLATION. OBSERVE ALL SET- <br /> <br /> <br />