My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1474399
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
97-XXXXX
>
BUILD - 1474399
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2019 2:42:16 PM
Creation date
8/19/2004 12:56:09 PM
Metadata
Fields
Template:
Permits
Permit Address
44000 NORTH SANTIAM HY SE
Permit City
Detroit
Permit Number
555-97-04116
Parcel Number
105E02 00300
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lancaster Dr. N.E. · Suite C · Salem, Oregon 97305-1398 <br />Office Hours: 8:00-4:30 · Phone: (503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br />DATE/TINE <br />TYPE <br />CLASS <br />OCCUPANCY <br />CONSTR!JCTIOfl <br /> <br /> BUILDINC PERNIT <br /> : 87/87/97 89=14 PERNIT NO : 97-841t6 <br /> = Ne# Commercial 9TATUS = ISSUED <br /> = S~ore~ Nercanti~e Building ISSUED = 87/87/1997 <br /> ~ N TO EXPIRE : 81/83/1998 <br /> : V-N PACE <br /> Architectural and Transportation Barriers Compliance Board, <br /> 1-202-~5~-7034 (Vote/TOD) or 1-SOO-USA-ABLE. Failure to <br /> comply with the ADA may resul~ in Federal fines and <br /> nenalties. <br /> ~. This is a Plan Review covering the construction of the <br /> above indicated new building. Plans have been reviewed for <br /> compliance with the provisions of the Oregon State <br /> Structural Specialty Codm ('94 UBC) 1996 Edition. <br /> ~2. SPECIAl.. HAZARDS. (OSSC Sec 389.8) <br /> Storage and use of flammable and combustible liquids shall <br /> be in accordance with the Fire Code. <br /> Devices generating a glow, spark or flame capable of <br /> igniting flammable va~ors shall be installed such that <br /> sources of ignition are at least 18 inches above the floor <br /> of any room which Class I flammable liquids or flammable <br /> ~ases are used or stored. <br /> 1~. [IVE LOADS POSTED. (OSSC Sec 1684.5) <br /> The live loads foe which each floor or part thereof of a <br /> commercial building is or has been designed shall have such <br /> designed live loads conspicuously posted by the owner in <br /> that part of each story in which they apply, using durable <br /> metal signs, and it shall be unlawful to remove or deface <br /> such notices. The occupant of the b~wlding shall be <br /> responsible for keeping the actual load below the allowable <br /> limits. <br /> The signs shall be: <br /> 1st Floor Live Load - 75 psf. <br /> 2nd Floor Live Load - 50APSf's.C TION <br /> 14. GLAZING IN HAZARDOUS LO (OSSC Sec 2405.4) <br /> Glazing in fixed or operable panels adjacent to a door where <br /> the nearest exposed edge of the glazing is within a 24-inch <br /> arc of either vertical edge of the door in a closed position <br /> and where the bottom exposed edge of the glazin~ os less <br /> than 60 ~nches above the walking surface shall ~e considered <br /> as a specific hazardous location. <br /> Safety glmzing material installed in hazardous locations <br /> shall be idenfified by a permanent label which specifies the <br /> labeler~ ~hether the manufacturer or installer, a? the <br /> state that safety gla~ing material has been utilized in such <br /> installation. <br /> ~5. STAIRWAYS. (OSSC Sec 100&) <br /> Stairways serving an occupant load of 4~ or less shall not <br /> be less than 36 inches in width. <br /> Private steps and stairwaXs serving an occupant load of tess <br /> than 10 May be constructe~ with art 8-inch-maximum rise and a <br /> 9-inch-minimum run. <br /> Stairways less than 44 inches in width may have one handrail <br /> 16. CONTACT PERSONS: <br /> ~Donald K. fl~ller, Deputy State Fire Marshal <br /> / State of Oreqon Fire Marshal <br />~/ 4760 Portlan~ Rd. NE <br /> Salem, Or. 97305 <br /> (503) 378-4917 <br /> FAX ~73-1825 <br /> Arlie Ellis, Chief <br /> Idanha-Detroit RFPD (flarion/Linn) <br /> PO Drawer B <br /> ~ Detroit. OR 97~42 <br /> X~,PH: (5~3) 854-~494 (Bs) M, Th; 8-12 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.