MARION COUNTY BUILDING INSPECTION <br /> COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 * Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 · Phone: (503) 588-5147 · 24-HR Inepection Line: (503) 588-7904 <br /> <br />DATE/TIME <br />TYPE <br />CLASS <br />OCCUPANCY <br />CONSTR!JCTIOH <br /> <br /> DUILDIN~ PERNIT <br /> .' B6/24/77 14=08 PERHIT NO : 97-~4B67 <br /> : Resident. addition/alteration STATUS : ISSUED <br /> : DNelling addition/alteration ISSUED : B6/24/1797 <br /> : R-~ TO EXPIRE : 12/21/1997 <br /> = V-H PAtE <br /> L&AWL HOL!~ P¥ovide ~n ~c(:ess cr~l ho~e to fha underfloor <br /> space., The mS.~5, mum size op~in~ ~eq~d.~-ed is lB inches by 24 <br /> inches~ [Sec. 4M?. 2] <br />/2. {JNDE)'YF'[.{)OR ])RAINS. The 'f:hd.s~hed grade of the underfloor <br /> ~ur~ac~ may be located at the botfom of the Tooting~ however <br /> wh~re there ~s evidence that the grot~+~dmater table ca~ rise <br /> to mithi?~ 6 i)'~cbes of the finJsh~d floor at the buildin~l <br /> ~e~-imeter or where there is ~vidence that the surface m~ter <br /> does not readily drain away from th~ buildi~g site, the <br /> gr'ad~ ~n the undert=loor space shall b+> as high as the <br /> o~tside f:~.n~sbe~ g~'ad~, tmless a¥~ approved d~-ai~age system <br /> <br />~., BF. This str{{cture uses Brace Wall Panels (Bt') to MeeO he <br /> c:od~ requ3rement for lateral wa!l bracing. Insure that ail <br /> BF'~s a~"~ ]ocate~, as indicated on the plahs. <br />~4. ?ANDARO CRU~SESS, girder tn~sses, hip masters, etc:, shall <br /> oe, desio'm'med and placed exactly as shown on the aoproved <br /> p~.a~'~['~d~)r'the ~o~rlow~d ~russ !ayout. If another design <br /> or layout is desi~'~d~ app]x fo¥ a~"~ AD~ENI)UM by submittin~ to <br /> this office two (2) se'ts of plans ref[~c'tJ.¥~q the desi~-ed' <br /> charities. Addendums are done at a $4~ per h~ur rats. Apply <br /> h~fors stac?nq construction. <br />~5. TRUSS DESI(;N.~ Roof trusses are required to be be designed 0y <br /> an Oregon registersd Engineer or Architect. For trusses <br /> manufactured by an approved fabrication plmnt~ ha~e the <br /> d~sign ~nd layout drawi~gs mvailable a't the construction <br /> site' for the ~'r~ming inspection, Ail jobsite cutting or <br /> modificatio~s of the roo~ trusses shall be clearly show~'~ i~ <br /> the e~q~n~¥~s d~sig~ ~lc~)ati~.o~s an~ d~"a~ings. <br />1~. ~M~K[ ~TECTORS ~hmll be :i. nstal'.;~d in each sleeping <br /> o~[~side of each separate sl~p~np e~'~a in the immmOiate <br /> vicinity of the b~(Jt"ooMs and on ~ech ~dditional story of the <br /> dwelling in~:luding b~sements~ All d~.tectors shall be inter- <br /> c:onnected ~uch t'.'h~t the actuation of on~ alarm will actuate <br /> ~11 the alarms in th~ i~'~dividu~], unit af~d shall provide <br /> eI~rm which will he ~u~Jib].e in ~[1 ~leepinq areas. <br /> [S~ctio¥~ ~14~I] Smok~ dete(~tors shall be ~18 volt with <br /> <br />~7~ EX'II~RIOR JOINTS around ~i¥~dows ~nd doo¥' frames~ between wail <br /> caviti~ a~d window or door fr~M~% he't'~een wall and <br /> foun~atio¥~ bet"wee' wa~ and -o(~f. between' ~all oanels~ at <br /> p~,~e'['r~tions or utility servic~s~ ~'h~ough walls~ 'floors and <br /> roofs and ~11 other op~ing~ in th~ exterior envelope shall <br /> be ~led i~ ~ maimer epprowd hy the Building Official. <br /> <br /> <br />