My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1475343
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
97-XXXXX
>
BUILD - 1475343
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2013 1:14:33 PM
Creation date
8/19/2004 1:07:33 PM
Metadata
Fields
Template:
Permits
Permit Address
135 4TH ST W
Permit City
Detroit
Permit Number
555-97-04959
Parcel Number
105E02AD04800
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
R~LM Consulting Services <br /> 3896 Beverly NE, Suite 22 o Salem o OR · 97305 <br /> <br />Tel: (503) 362-0920 <br /> <br />Fax: (503) 362-2283 <br /> <br />CONDITIONS REQUIRED: <br /> <br />THIS PLAN REVIEW was completed by RLM CONSULTING SERVICES <br />PLANS EXAMINER:~ on ~ I~/d~119 <br />ACTIVITY NO. 97-04959 <br /> <br />RLM NO. 97-0245 <br /> <br />CONDITIONS REQUIRED: <br /> <br />1. LOT DRAINAGE. Lots shall be provided with adequate drainage and shall be graded so as <br />to drain surface water away from foundation walls. The grade away from foundation walls shall <br />fall a minimum of 6 in. within the first 10 ft. Where lot lines, walls or other physical barriers <br />prohibit 6" of fall within 10 feet, drains or other approved means shall be provided to ensure <br />positive drainage. [Sec. 401 <br /> <br />2. CONCRETE SPECIFICATIONS. Basement walls and foundations not exposed to the <br />weather, basement slabs and interior slabs on grade, except garage floor and steps exposed to <br />the weather shall have a minimum compressive strength of 2500 psi. Basement walls, foundation <br />walls, exterior walls, and other vertical concrete work exposed to the weather, porches, carport <br />slabs, and steps exposed to the weather, and garage floor slabs shall have a minimum specified <br />compressive strength of 3000. Concrete shall be air entrained. Total air content (percent by <br />volume of concrete) shall not be less than 5 percent or more than 7 percent. [Sec. 402.2, Table <br />402.2] <br /> <br />3. FOUNDATION SIZE. Footing and Foundation size minimum requirements: <br />Floors supported Footing size Stem Wall Thickness <br /> 1 6"x 12" 6" <br /> 2 7"x 15" 8" <br /> 3 8"x 18" 10" <br /> [Table 403.2] <br /> <br />4. A KEYWAY in the footing is an acceptable method and will transfer the lateral loads, OR <br />provide 18 inch long, No. 3 dowels extending 12 inches from the footing into the wall, 4 feet on <br />canter, OR pour the footing stemwall at one time (monolithically). All wood left permanently in <br />contact with the ground shall be F ATI WiTH ALL CUT ENDS AND/OR <br />SIDES TREATED with an approved wood preservative. [Sec. 322.1(5)] <br /> <br />5. BP,PF ATTACHED. This structure uses a combination of Brace Wall Panels (BP) and Portal <br />Frame(s) to meet the code requirements for lateral wall bracing. Insure that all BP's and Portal <br />Frame(s) are located as indicated on the plans and constructed as shown on the plans and the <br />attached detail sheets. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.