Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lancaster Dr. N.E. · Suite C · Salem, Oregon 97305-1398 <br />Office Hours: 8:00-4:30 · Phone: [503) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br /> SITE EVALUaTION/SEPTIC PERH[T <br />~,~TE/T[HE = 12/24/97 12=37 PERHZT HO = 97-~94~9 <br />TYPE = SESP STATUS = ISSUED <br />~OCCUP~ICY = R-3 [SSI.lED = 12/24/1997 <br /> TO EXPIRE = 12/24/1998 <br /> PAGE 3 <br /> <br /> SITE EVALUATION APPROVAL AND SEPTIC PERMIT <br /> <br />This property has been evaluated for the feasibility of the installation of a septic <br />system fOL' a RESIDENTIAL buiIding site. Based on the results of this study, site evaluation <br />~pproval was granted. The approval is s~ecific to the area tested, arid ~h~ ~ep~ sy~'~M mUS~ be <br />~r,c~t~d in the iMMediat~e'area of the test pits~ unless otherwise authorized Oy ~nss OTt~ce. H <br />~w site evaluation na~ be required if the system is proposed for a different area on the property. <br />*[hfs approva] is Given on the basis tha~ the lot or parcel will not be further partitioned <br />or subdivided and~hat conditions on thi~ property and on adjacent propel'ties are ~ot altered in <br />e~y Manner which would prohibit the issuance of a perMit~ Soils in the approved area shall ~lot be <br />altered or modified by cutting~ fiIlin~, or other d~velopMental activities which would impede the <br />s~tccessful operation of the instial or replacement soil absorption systems. Failure to coMp].y with <br />the above items May void thi~ approval. <br /> <br />This site evaluation approval runs with the land~ but the permit is non-transferable and <br />no~-refundable. <br /> <br />Ke~p this docUMent ~ith your records. Show this permit t'o the septic installer prior to <br />installation of the SyStem. Any deviation from the approved plan ~ust have prior approval fro~ <br />this offil:e. <br /> <br />The following construction specifications sh~ll apply to the installation of the i~itial <br />s~ptic system: <br /> <br /> TYPE OF INITIAL SYSTEM: STANDARD <br /> MXNIMUM SEPTIC TANK CAPACITY: 1008 GALLONS <br /> LINEAL FEET OF ~RAINFIELD: 375 <br /> TYPE OF DISTRIBUTION: E~UAL <br /> DISPOSAL TRENCH DEPTH: 18INCHES, MINIMUM; 24INCHES, MAXIMUM <br /> TOTAL DRAIN MEDIA DEPTH: 12INCHES <br /> DRAIN ME~IA NHDER PIPE: 4INCHES <br /> MINIMUM SOIL. BACKFILL= 6INCHES <br /> GROUND WATER INTERCEPTOR: N <br /> <br />The d~sposal trenches are'constructed (2) feet wide and on MiMiMUM ten (10) foot centers <br />and with no line exceeding 125 feet in length. The trenches ~and Berforat.'ed pi~pe are <br />installed level (+/- one ~nch) and conto[~red to follow the na~ura~ grouno sur~'ace. <br /> <br />TYPE OF FUTURE REPLACEMENT SYSTEM: STANDARD <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1. THIS sEPTIc REVIEW WAS COMPLETED BY ROBERT FOSTER on <br /> DECEMBER '2~. 1997. <br /> LOCATE THE BRAINFIELD AS SHOWN ON THE ATTACHED SITE PLAN, <br /> ALONG THE NORTH PROPERTY LINE ADJACENT TO THE FILBERT <br /> ORCHARd. ~TAKE OUT THE DRAtNFIELD FOR THIS HOUSE AND THE <br /> DRAINFtELD FOR HOUSE fl PRIOR TO CONSTRUCTING THE SYSTEMS. <br /> MAINTAIN A FIFTY (50) FOOT SEPARATION BETWEEN THE SEPTIC <br /> ~ SYSTEMS AND TNE ESCARPMENT OF THE RAVINE TO THE SOUTH. <br />2. The attached ORANGE CARD MUS'~ be posted at the county road. <br />~. The site Must be protected from traffic, livestock, farthing <br /> or other damaging activities. <br />4~ This system Must he inspected prior ~o covet*. When work is <br /> complete, call our AutoMate~ Inspection ReqoeSt Line, <br /> at 37~-4427, to request an 801" PRE-I,OVER inspection. <br /> <br /> <br />