Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lancaster Dr. N.E. · Suite C · Salem, Oregon 97305.1398 <br />Office Hours: 9:00-4:30 * Phone: (503) 588,5147 * 24-HR Inspection Line: (503) 373.4427 <br /> <br /> BUILDING PERMIT <br />DATE/TIHE ~ 12/23/97 16~26 PERH[T HO ~ 97-e9§38 <br />TYPE : Residential accessory struct STATU~ : ISSUED <br />OCCUP~d~CY : U-1 ISSUED : 12/23/1777 <br />COHST TYPE = V-H TO EXPIRE ; B6/21/1978 <br /> PAgE 2 <br /> <br />RFQ .[RFD SETBACKS: ~ront. <br /> <br />PLAN REVIEW CO~!MENTS AND CONDITIONS <br /> <br /> Left: ~0 Right: 5 Rear: 5 Special: <br /> <br />THIS PLAN REVIEW WAS C(/HPI.ETED BY M. LITTLE ON 12/22/77. <br />Approval of submitted plans is not an approval of omissions <br />or over~ghts by this office or of noncompliance w~th any <br />~pplic~bl~ re~lations of.local ~over~ment. <br />~ATTENTION~ THIS STRU(,TIIRE USES BRACE WALL RANELS TO MEE <br />T THE CODE REQUIRE~4ENT FOR LATERAL BRACIWG.EXTERIOR WALL PAN <br />ELS OF FRAME CONSTRUCTION SHALL ~E BRACED WITH APPROVED STRU <br />CTIIRAL SHEATH~NG. XHSURE THAT ALL BP~S ARE LOCATED AS IN~ICAI' <br />ED Ol,I THE~ PLANS. <br />SfANI)A~ TRUSSESS. girder trusse% hip Masters~ etc.~ shell <br />be designed and placed exactly as shown on the approved <br />pla~m and/or the ~p~roved truss layout. <br />or ].ayou'~ is desired~ apply for en ADDENDUM by submitting to <br />this offi~:e two (2) sets of pla~s reflecti~ the desired <br />chen~es. Adde~duMs are done at a S48 per hour rate. Apply <br />before s~m~tioq construction. <br />TRUSS DESIGN. Roof trusses are required to be be designed by <br />~o Oregoo r~istered E~gineer or Architect. For trusses <br />Man~faEtu~'ed by an approved fabrication plant, have the <br />design and ].ayout drawings available at the constructio~ <br />s~te for the Yr~ing inspection. All jobsite cutting or <br />~od~?icetioms of th~ roof trusses sh~ll be clearly s~own in <br />the e~g~neer~s design calculations an~ drewi~Qs. <br />***ATTENTION*** IF GARAGE INTERIOR IS TO BE FINISHED THAN A <br />READILY ACCKSSABLE ATTIC ACCESS SHALL BE PROVIDED TO ANY ATT <br />IC AREA HAVING A CLEAR HIGHT OF OVER ~8 INCHES.A FRAMED OPEN <br />ING NOT LESS T~AN 22" X S~" IS RE~UIRED. <br />LANDING / EXTERIOR DOOR. A mini~,.~M S foot x ~ foot landing <br />shall be ~'equi~ed o~'* each si~e of ~ egress doo~. The <br />or la,ding shall ~ot be More then 1 a~ 1~2 inches lower <br />than the top of th~ th~'eshold. Exceptioo. The lm~di~g at <br />the exterior doorway Shall ont be ~ore than 8 1/4 i~ches <br />below the~top of the threshold. [Sec. <br />***ATTENTION*** A MIH[HUM OF 6 FEET SHALL BE PROVIDED BETWEE <br />N THE DWELLING AND THE PROPOSED GARAGE AS INOlCATED ON THE <br />APPROVE~ SITE PLAN OR PROVIDE A COMPLETE SEPPERATION BY MEAN <br />S OF 1/~ INCH SHEET ROCK. <br />NON-HFATED STRUCTURE. This structure is being reviewed as <br />non-heated structure. If the building is to be heated, <br />mpply for a~ ~dOendum to these pla~s by submitting revised <br />plans showin~ how th~s s~ructure will Meet the requirements <br />of th~ O~egon E~ergy Code. Apply before startin9 co~st~oc- <br />tion. <br /> <br /> <br />