21. FIRESTOPPING shall be provided in the following locations: <br />1) In concealed spaces of stud wails, including furred spaces not to exceed 10 feet ho <br />dzontally, and at the ceiling and floor level. <br />2) At all interconnections between concealed vertical and horizontal spaces such as occur at <br />soffits, drop or cove ceilings, etc. <br />3) In concealed spaces between stair stdngem at the top and bottom of the mn and wall cavities <br />in line with the stdngem; <br />4) At openings around vents, pipes, ducts, chimneys and fireplaces at ceiling and floor level, with <br />noncombustible rnatedals. [Sec. 602.7] <br /> <br />22. COMBUSTION AIR. Fuel buming equipment shall be provided with a suff~cient supply of <br />air for fuel combustion, draft hood dilution and ventilation of the space in which the equipment is <br />installed. Plans do not show how combustion air is going to be provided. See the manufacture- <br />r's installation instructions and Chapter 20 of the State of Oregon One and Two Family Dwelling <br />Specialty Code for guidance. [Sec. 2001.1] <br /> <br />23. ENERGY PATH #1 is based on R-21 wall insulation, R-25 underfloor insulation, R-30 <br />vaulted ceiling insulation, R-38 fiat ceiling insulation, R-21 basement walls, R-15 slab floor edge <br />insulation, R-8 forced air duct insulation, 0.40 U-value window class, 0.50 U-value skylight class, <br />0.54 U-value main entry door, (with a maximum area of 24 square feet) all other exterior doom, <br />including the door between the heated dwelling and the unheated garage, 0.20 U-value. <br /> <br />Basement Area <br />First Floor Area <br />Second Floor Area <br />Third Floor Area <br />Gaea~e Area <br />Total Area <br /> <br />1884sf <br />1535sf <br />1526sf <br /> 658sf <br /> 440sf <br />6043sf <br /> <br />Robert L. Mendenhall <br />KLM Consulting Services <br />98-00200.wps <br /> <br /> <br />